Name: | D. T. PAINTING & MAINTENANCE INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 19 Jan 2016 (9 years ago) |
Entity Number: | 4880879 |
ZIP code: | 14219 |
County: | Erie |
Place of Formation: | New York |
Address: | 4937 MILESTRIP ROAD, BLASDELL, NY, United States, 14219 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
DANE TANEVSKI | DOS Process Agent | 4937 MILESTRIP ROAD, BLASDELL, NY, United States, 14219 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
160119010117 | 2016-01-19 | CERTIFICATE OF INCORPORATION | 2016-01-19 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346909765 | 0213600 | 2023-08-14 | 6619 TRANSIT RD, WILLIAMSVILLE, NY, 14221 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2023-08-30 |
Current Penalty | 2419.5 |
Initial Penalty | 3226.0 |
Final Order | 2024-04-01 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 08/14/2023, at a home and garage roof project located at 6619 Transit Rd, Williamsville, NY; employees were painting on the roof of a two story hotel. The roof had multiple pitches including an 5 in 12 pitch with an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2023-08-30 |
Current Penalty | 1935.0 |
Initial Penalty | 2580.0 |
Final Order | 2024-04-01 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A body belt (harness) shall be worn and a lanyard attached to the boom or basket when working from an aerial lift: a) On or about 08/14/2023, during the painting of a roof of a located at 6619 Transit Rd Williamsville, NY; the employer did not enforce the use of fall protection to employees working in the basket of an aerial boom lift, 18 feet above lower levels. Employees were allowed to work in an articulating boom without the use of Personal Fall Arrest Systems and "tying off" to the boom basket with a lanyard. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2023-08-30 |
Current Penalty | 1451.25 |
Initial Penalty | 1935.0 |
Final Order | 2024-04-01 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed. a) On or about 08/14/2023 at the roof area of the site, side rails of the extension ladder did not extended 3 feet above the upper landing surface being accessed. Employees were exposed to falls. NO ABATEMENT CERTIFICATION REQUIRED |
Date of last update: 25 Mar 2025
Sources: New York Secretary of State