OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343061313 0213600 2018-04-04 1715 JEFFERSON AVENUE, BUFFALO, NY, 14208
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-04-04
Emphasis P: FALL, L: FALL
Case Closed 2024-04-01

Related Activity

Type Inspection
Activity Nr 1307044
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2018-04-10
Current Penalty 2000.0
Initial Penalty 2772.0
Contest Date 2018-05-04
Final Order 2018-07-23
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. a) On or about 04/04/18 at 1715 Jefferson Avenue, Buffalo, NY; employees were exposed to a 17 foot fall hazard when employees used the support ladders and ladder jack scaffold cross braces as a means of access to the ladder jack scaffold. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Other
Standard Cited 19260451 F03
Issuance Date 2018-04-10
Current Penalty 0.0
Initial Penalty 2772.0
Contest Date 2018-05-04
Final Order 2018-07-23
Nr Instances 1
Nr Exposed 2
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: a) On or about 04/04/18 at 1715 Jefferson Avenue, Buffalo, NY; employees were exposed to a 17 foot fall hazard when one of the aluminum support ladders for the ladder jack scaffold they were working on, to secure roof tarps, had two damaged rungs. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G01 I
Issuance Date 2018-04-10
Current Penalty 2800.0
Initial Penalty 3880.0
Contest Date 2018-05-04
Final Order 2018-07-23
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(i): Each employee on a ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 04/04/18 at 1715 Jefferson Avenue, Buffalo, NY; employees working from a ladder jack scaffold securing tarps to the roof were exposed to a 17 foot fall hazard when they did not have fall protection. NO ABATEMENT CERTIFICATION REQUIRED
342504594 0213600 2017-07-26 128 KENEFICK AVENUE, BUFFALO, NY, 14220
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-07-26
Emphasis L: FALL, P: FALL
Case Closed 2017-10-23

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2017-08-17
Current Penalty 2852.25
Initial Penalty 3803.0
Final Order 2017-09-12
Nr Instances 1
Nr Exposed 7
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 07/26/17, on the roof of a house at 128 Kenefick Avenue , Buffalo, NY: Employees engaged in roofing tearoff on the west side, and shingling work on the east side of the steep roof were exposed to a fall of approx. 18 ft. No fall protection system was utilized. Pitch of the roof was 12 in 12. NO ABATEMENT DOCUMENTATION REQUIRED
Citation ID 01002A
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2017-08-17
Current Penalty 2037.0
Initial Penalty 2716.0
Final Order 2017-09-12
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) On or about 07/26/17, on the east side of the house at 128 Kenefick Avenue, Buffalo, NY : Employees used an extension ladder to access the roof which was approx. 18 ft. above the ground. The side rails of that ladder only extended approx. 19 inches above the roof. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2017-08-17
Abatement Due Date 2017-09-18
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-09-12
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) On or about 07/26/17, on roofing jobsite on a house at 128 Kenefick Avenue, Buffalo, NY: Employees engaged in construction work including roofing & clean-up were not trained to recognize potential hazards on this type of jobsite, including but not limited to falls from roofs, ladders, skylights, scaffolds, electrical hazards, unguarded tools/machines, fire hazards, and the need for personal protective equipment to protect them from various hazards. They also were not trained in the applicable OSHA regulations to control or eliminate these hazards. ABATEMENT CERTIFICATION REQUIRED
342338480 0213600 2017-05-18 33 GEORGE URBAN BLVD., CHEEKTOWAGA, NY, 14225
Inspection Type Complaint
Scope Partial
Safety/Health Health
Close Conference 2017-07-11
Case Closed 2023-05-05

Related Activity

Type Complaint
Activity Nr 1237304
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19261101 F01 I
Issuance Date 2017-07-27
Current Penalty 2892.0
Initial Penalty 2716.0
Final Order 2017-10-16
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(f)(1)(i): Where exposure monitoring was required under 29 CFR 1926.1101, the employer did not perform monitoring to determine accurately the airborne concentrations of asbestos to which employees were or potentially were exposed: a) 33 George Urban Boulevard, Cheektowaga, NY - On or about 05/18/2017, employees performed the removal of asbestos-containing materials (slate roofing materials which contained 15% asbestos) manually and with roofing shears. The employer did not perform exposure monitoring to determine the airborne concentrations of asbestos to which employees performing Class II asbestos work were exposed. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261101 G01
Issuance Date 2017-07-27
Current Penalty 0.0
Initial Penalty 2716.0
Final Order 2017-10-16
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(g)(1): The employer did not use engineering controls and work practices in all operations covered by 29 CFR 1926.1101, regardless of the levels of the exposure: a) 33 George Urban Boulevard, Cheektowaga, NY - On or about 05/18/2017, employees performed the removal of asbestos-containing materials (slate roofing materials contained 15% asbestos) manually and with roofing shears. The employer did not use appropriate engineering controls and work practice controls during the asbestos removal. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001C
Citaton Type Serious
Standard Cited 19261101 G07
Issuance Date 2017-07-27
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2017-10-16
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(g)(7): The work practices and engineering controls listed in sections (i) through (iv) of this paragraph were not used for Class II work: a) 33 George Urban Boulevard, Cheektowaga, NY - On or about 05/18/2017, employee performed the removal of asbestos-containing materials (slate roofing materials contained 15% asbestos) manually and with roofing shears. The employer did not use appropriate engineering controls and work practice Class II work. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261101 H02 I
Issuance Date 2017-07-27
Current Penalty 2892.0
Initial Penalty 2716.0
Final Order 2017-10-16
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(h)(2)(i): The employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii), and (f) through (m): a) 33 George Urban Boulevard, Cheektowaga, NY - On or about 05/18/2017, where employees were performing Class II asbestos work while removing asbestos-containing materials (slate roofing materials containing 15% asbestos) manually and with roofing shears, the employer did not implement a respiratory protection program in accordance with 29 CFR 1910.134(b) through (d) (except (d)(1)(iii), and (f) through (m). NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261101 I01
Issuance Date 2017-07-27
Current Penalty 0.0
Initial Penalty 2716.0
Final Order 2017-10-16
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(i)(1): The employer did not provide and require the use of protective clothing, such as coveralls or similar whole-body clothing, head coverings, gloves, and foot coverings for each employee exposed to airborne concentrations of asbestos that exceed the time weighted average and/or excursion limit in 29 CFR 1926.1101(c) or for which a required negative exposure assessment was not produced: a) 33 George Urban Boulevard, Cheektowaga, NY - On or about 05/18/2017, employees performed the removal of asbestos-containing materials (slate roofing materials contained 15% asbestos) manually and with roofing shears. The employer did not provide and require the use of protective clothing, such as coveralls or similar whole-body clothing, head coverings, gloves, and foot coverings for each employee exposed to airborne concentrations of asbestos. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01006
Citaton Type Serious
Standard Cited 19261101 K09 I
Issuance Date 2017-07-27
Current Penalty 2716.0
Initial Penalty 2716.0
Final Order 2017-10-16
Nr Instances 1
Nr Exposed 5
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1101(k)(9)(i): The employer did not ensure participation in the asbestos training program by each employee who was likely to be exposed to asbestos in excess of the permissible exposure limit (PEL), or for each employee engaged in Class I through Class IV asbestos operations: a) 33 George Urban Boulevard, Cheektowaga, NY - On or about 05/18/2017, employees performed the removal of asbestos-containing materials (slate roofing materials contained 15% asbestos) manually and with roofing shears. Employees performing these Class II activities had not received appropriate training. NO ABATEMENT CERTIFICATION REQUIRED

U.S. Small Business Administration Profile

Status User ID Name of Firm Trade Name UEI Address
Active P2861936 AMYCO CONSTRUCTION LLC - C191UM5J7JV1 2 SUGARBUSH WAY, ORCHARD PARK, NY, 14127-4641
Capabilities Statement Link -
Phone Number 716-345-2288
Fax Number -
E-mail Address amycoconstruction@gmail.com
WWW Page -
E-Commerce Website -
Contact Person AMY GOODING
County Code (3 digit) 029
Congressional District 23
Metropolitan Statistical Area 1280
CAGE Code 7X4L7
Year Established 2015
Accepts Government Credit Card Yes
Legal Structure Partnership
Ownership and Self-Certifications Women-Owned Small Business, Woman Owned
Business Development Servicing Office BUFFALO DISTRICT OFFICE (SBA office code 0296)
Capabilities Narrative (none given)
Special Equipment/Materials (none given)
Business Type Percentages (none given)
Keywords (none given)
Quality Assurance Standards (none given)
Electronic Data Interchange capable -

SBA Federal Certifications

HUBZone Certified No
Women Owned Certified No
Women Owned Pending No
Economically Disadvantaged Women Owned Certified No
Economically Disadvantaged Women Owned Pending No
Veteran-Owned Small Business Certified No
Veteran-Owned Small Business Joint Venture No
Service-Disabled Veteran-Owned Small Business Certified No
Service-Disabled Veteran-Owned Small Business Joint Venture No

Bonding Levels

Description Construction Bonding Level (per contract)
Level (none given)
Description Construction Bonding Level (aggregate)
Level (none given)
Description Service Bonding Level (per contract)
Level (none given)
Description Service Bonding Level (aggregate)
Level (none given)

NAICS Codes with Size Determinations by NAICS

Primary Yes
Code 238290
NAICS Code's Description Other Building Equipment Contractors
Buy Green Yes

Export Profile (Trade Mission Online)

Exporter Firm hasn't answered this question yet
Export Business Activities (none given)
Exporting to (none given)
Desired Export Business Relationships (none given)
Description of Export Objective(s) (none given)

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
2895875 Intrastate Non-Hazmat 2023-05-23 8714 2022 2 1 Auth. For Hire, Private(Property)
Legal Name AMYCO CONSTRUCTION LLC
DBA Name -
Physical Address 2 SUGARBUSH WAY, ORCHARD PARK, NY, 14127-2032, US
Mailing Address 2 SUGARBUSH WAY, ORCHARD PARK, NY, 14127-2032, US
Phone (716) 342-5357
Fax (716) 345-2288
E-mail AMYCOCONSTRUCTION@GMAIL.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 25 Mar 2025

Sources: New York Secretary of State