Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2018-10-16
|
Emphasis |
L: FORKLIFT, N: AMPUTATE
|
Case Closed |
2019-12-06
|
Related Activity
Type |
Referral |
Activity Nr |
1410072 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19100147 C04 I |
Issuance Date |
2019-04-12 |
Abatement Due Date |
2019-05-01 |
Current Penalty |
2785.0 |
Initial Penalty |
3978.0 |
Final Order |
2019-04-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(4)(i): Procedures were not developed, documented and utilized for the control of potentially hazardous energy when employees were engaged in activities covered by this section: a) Worksite: Employee expected to perform cleaning, repair, and maintenance work on JWC-CFD under pad machine, powered by energy sources such as, but not limited to, electrical and pneumatic components, was neither provided with nor utilizing energy control procedures; on or about 10/16/18. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19100147 C05 I |
Issuance Date |
2019-04-12 |
Abatement Due Date |
2019-05-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-04-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(5)(i): Locks, tags, chains, wedges, key blocks, adapter pins, self-locking fasteners, or other hardware were not provided by the employer for isolating, securing or blocking of machines or equipment from energy sources: a) Worksite: Employee expected to perform cleaning, repair, and maintenance work on JWC-CFD under pad machine, powered by energy sources such as, but not limited to, electrical and pneumatic components, was not provided with hardware to lock out the pneumatic component(s); on or about 10/16/18. Note: Abatement certification is required for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19100147 C07 I A |
Issuance Date |
2019-04-12 |
Abatement Due Date |
2019-05-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-04-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.147(c)(7)(i)(A): Authorized employee(s) did not receive training in the recognition of applicable hazardous energy sources, the type and magnitude of the energy available in the workplace, and the methods and means necessary for energy isolation: a) Worksite: Employee was expected to perform cleaning, repair, and maintenance work on JWC-CFD under pad machine, powered by energy sources such as, but not limited to, electrical and pneumatic components. Authorized employee was not provided with the applicable training regarding the control of hazardous energy; on or about 10/16/18. Note: Abatement certification is required for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19100178 L01 I |
Issuance Date |
2019-04-12 |
Abatement Due Date |
2019-05-01 |
Current Penalty |
2785.0 |
Initial Penalty |
3978.0 |
Final Order |
2019-04-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(1)(i): The employer did not ensure that each powered industrial truck operator is competent to operate a powered industrial truck safely, as demonstrated by the successful completion of the training and evaluation specified in this paragraph (l): a) Worksite: Employee was authorized to operate powered industrial trucks, such as a Crown forklift, without receiving training and evaluation; on or about 10/16/18. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19100178 L04 III |
Issuance Date |
2019-04-12 |
Abatement Due Date |
2019-05-01 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2019-04-16 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.178(l)(4)(iii): An evaluation of each powered industrial truck operator's performance was not being conducted at least once every three years: a) Worksite: Employee authorized to operate powered industrial trucks, such as a Crown forklift, had not received a performance evaluation in the safe operation of powered industrial trucks in over at least three years; on or about 10/16/18. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|