Name: | BUILDERS CONSTRUCTION INC |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 25 Feb 2016 (9 years ago) |
Entity Number: | 4902412 |
ZIP code: | 11373 |
County: | Queens |
Place of Formation: | New York |
Address: | 5016 JUNCTION BLVD 1FL, ELMHURST, NY, United States, 11373 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 5016 JUNCTION BLVD 1FL, ELMHURST, NY, United States, 11373 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
160225010267 | 2016-02-25 | CERTIFICATE OF INCORPORATION | 2016-02-25 |
Number | Adjudicates | Phase | Disposition | Date | Fine amount | Date fine paid | description |
---|---|---|---|---|---|---|---|
TWC-223603 | Office of Administrative Trials and Hearings | Issued | Settled - Pending | 2022-03-22 | 0 | No data | Removed collected or disposed of trade waste or without the proper Commission issued license or exemption from licensing requirements |
TWC-221579 | Office of Administrative Trials and Hearings | Issued | Settled - Pending | 2021-04-17 | 0 | No data | Removed collected or disposed of trade waste or without the proper Commission issued license or exemption from licensing requirements |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346584410 | 0215000 | 2023-03-23 | 470 2ND ST, BROOKLYN, NY, 11201 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
343929642 | 0215000 | 2019-04-09 | 850 57TH ST., BROOKLYN, NY, 11220 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2019-09-23 |
Current Penalty | 5304.0 |
Initial Penalty | 5304.0 |
Final Order | 2020-02-28 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface (horizontal and vertical surface) with an unprotected side or edge which is 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) Top of roof bulkhead: Two employees were building parapet walls with cinder blocks at unprotected edges of the roof bulkhead without fall protection, and were exposed to falling approximately 50 feet to ground. On or about 04/09/19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19261052 B01 |
Issuance Date | 2019-09-23 |
Current Penalty | 3789.0 |
Initial Penalty | 3789.0 |
Final Order | 2020-02-28 |
Nr Instances | 1 |
Nr Exposed | 3 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1052(b)(1): Foot traffic was not prohibited on stairways where the treads and/or landings of pan stairs were to be filled in with concrete or other material at a later date and stairs were not temporarily fitted with wood or other solid material at least to the top edge of each pan. a) Stairways between ground floor and the 4th floor: Employees used a stairway to travel between ground floor and the 4th floor. The treads of pan stairs were not filled or fitted with wood or other solid materials at least to the top edge of each pan to prevent tripping hazard. On or about 04/09/19. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2019-09-23 |
Current Penalty | 5304.0 |
Initial Penalty | 5304.0 |
Final Order | 2020-02-28 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed. a) 3rd floor balcony: An employee leaned a folded A-frame stepladder against a wall and climbed on the ladder for elevation to remove debris. The stepladder was not designed to be climbed on in the folded form for work elevation. On or about 04/09/19. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2019-04-02 |
Emphasis | L: LOCALTARG, P: LOCALTARG |
Case Closed | 2019-09-11 |
Loan Number | Loan Funded Date | SBA Origination Office Code | Loan Delivery Method | Borrower Street Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
5222557407 | 2020-05-12 | 0202 | PPP | 5016 JUNCTION BLVD 1ST FLOOR, ELMHURST, NY, 11373 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Date of last update: 25 Mar 2025
Sources: New York Secretary of State