Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2022-09-16
|
Emphasis |
N: TRENCH
|
Case Closed |
2024-04-19
|
Related Activity
Type |
Referral |
Activity Nr |
1948300 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260651 J02 |
Issuance Date |
2023-03-15 |
Current Penalty |
0.0 |
Initial Penalty |
3349.0 |
Contest Date |
2023-06-05 |
Final Order |
2024-01-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary. a) Worksite, 82 School Street, Glen Cove, NY - Employee was working in an excavation approximately 11 feet in depth with the spoil pile placed at the edge of the excavation on; on or about 9/16/2022. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260651 K01 |
Issuance Date |
2023-03-15 |
Abatement Due Date |
2023-03-21 |
Current Penalty |
0.0 |
Initial Penalty |
3349.0 |
Contest Date |
2023-06-05 |
Final Order |
2024-01-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.651(k)(1): An inspection of the excavations, the adjacent areas, and protective systems was not conducted by the competent person prior to the start of work and as needed throughout the shift: a) Worksite, 82 School Street, Glen Cove, NY - Employees were working in an excavation approximately 11 feet in depth that was not inspected by a competent person prior to work; on or about 9/16/2022. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260652 A01 |
Issuance Date |
2023-03-15 |
Abatement Due Date |
2023-03-21 |
Current Penalty |
0.0 |
Initial Penalty |
3349.0 |
Contest Date |
2023-06-05 |
Final Order |
2024-01-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.652(a)(1):Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c). a) Worksite, 82 School Street, Glen Cove, NY - Employee was working in an excavation approximately 11 feet in depth. There was no adequate protective system to protect employees; on or about 9/16/2022. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19261053 B01 |
Issuance Date |
2023-03-15 |
Abatement Due Date |
2023-03-21 |
Current Penalty |
0.0 |
Initial Penalty |
2679.0 |
Contest Date |
2023-06-05 |
Final Order |
2024-01-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1053(b)(1):Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: a) Worksite, 82 School Street, Glen Cove, NY - Employees were working in an excavation approximately 11 feet in depth using an aluminum ladder that extended only to ground level; on or about 9/16/2022. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19. |
|
|