OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343558714 0213100 2018-10-25 15 PRINCE STREET, WARWICK, NY, 10990
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2018-10-25
Emphasis N: TRENCH
Case Closed 2022-01-12

Related Activity

Type Referral
Activity Nr 1394662
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260021 B02
Issuance Date 2019-04-09
Current Penalty 2000.0
Initial Penalty 3978.0
Final Order 2019-05-08
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his/her environment to control or eliminate any hazards or other exposure to illness or injury: a) 15 Prince Street, Warwick, NY - On or about October 24, 2018, an employee was working in a trench at a depth of 6-8 feet and had never received training about the hazards of working in or near open trenches. The trench caved-in resulting in the hospitalization of the employee.
Citation ID 02001
Citaton Type Willful
Standard Cited 19260652 A01
Issuance Date 2019-04-09
Current Penalty 18000.0
Initial Penalty 26520.0
Final Order 2019-05-08
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Referral
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) 15 Prince Street, Warwick, NY - On or about October 24, 2018, employees were working in a trench at a depth of 6-8 feet with no cave-in protection in place. The trench caved-in resulting in the hospitalization of an employee.