OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344103536 0213600 2019-06-24 2400 GRAND ISLAND BLVD., GRAND ISLAND, NY, 14072
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-06-24
Emphasis N: SSTARG16, P: SSTARG16
Case Closed 2019-09-16

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100303 B02
Issuance Date 2019-08-16
Abatement Due Date 2019-09-18
Current Penalty 4830.0
Initial Penalty 6440.0
Final Order 2019-09-04
Nr Instances 4
Nr Exposed 10
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2): Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 06/24/19 at Anne's Fudge shop; a relocatable power tap was used to supply power to a popcorn machine exposing employees to burns. b) On or about 06/24/19 at Midway Pizza shop; a relocatable power tap was used to supply power to a nacho chip warmer, nacho sauce warmer and soda dispenser and ice machine exposing employees to burns. c) On or about 06/24/19 in the Maintenance shop; two relocatable power taps were being used to supply power to a microwave, two coffee makers, a battery charge and other miscellaneous equipment on a workbench exposing employees to burns. d) On or about 06/24/19 in the Maintenance shop; a relocatable power tap was mounted on the wall near the ceiling and used to supply power to the time keeping device and other computer network equipment exposing employees to burns. e) On or about 06/24/19 at the Flight Ride area; the HPS Sentinel G transformer part number SG30A150KY ( dry type ) was being used while mounted on a pallet, which was not allowed by the installation instructions provided by the manufacturer exposing employees to burns. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100305 J01 I
Issuance Date 2019-08-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-09-04
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(j)(1)(i): Fixtures, lampholders, lamps, rosettes, and receptacles located within 8 feet of the floor had live parts exposed to employee contact: a) On or about 06/24/19 in the maintenance shop; employees were exposed to contact with 120 volts AC when two outlets used to supply power to a group of battery charges were missing cover plates. NO ABATEMENT CERTIFICATION REQUIRED