Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342987161 | 0215000 | 2018-02-06 | 677 VANDERBILT AVENUE, BROOKLYN, NY, 11238 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1293398 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1298983 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 B02 |
Issuance Date | 2018-04-06 |
Abatement Due Date | 2018-04-12 |
Current Penalty | 3500.0 |
Initial Penalty | 5174.0 |
Final Order | 2018-04-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide. Location: a) Scaffold on the stairway between the fourth floor and the roof: On or about 02/06/18, two employees were installing sheetrocks while standing on folded A-Frame ladders that was on a scaffold platform supported by a ladder and the step of stair. The scaffold platform was not at least 18 inches wide. Employees are exposed to falling approximately 12 feet to the fourth floor ground level. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 C02 II |
Issuance Date | 2018-04-06 |
Abatement Due Date | 2018-04-12 |
Current Penalty | 3500.0 |
Initial Penalty | 5174.0 |
Final Order | 2018-04-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units. Location: a) Scaffold on the stairway between the fourth floor and the roof: On or about 02/06/18, two employees were installing sheetrocks while standing on folded A-Frame ladders that was on a scaffold platform supported by a ladder and the step of stair. The scaffold platform is not supported by stable object. Employees are exposed to falling approximately 12 feet to the fourth floor ground level due to scaffold collapse. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 F07 |
Issuance Date | 2018-04-06 |
Abatement Due Date | 2018-04-12 |
Current Penalty | 2375.0 |
Initial Penalty | 3696.0 |
Final Order | 2018-04-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration. Location: a) Scaffold on the stairway between the fourth floor and the roof: On or about 02/06/18, a supported scaffold was not erected under the supervision and direction of a competent person qualified in scaffold erection. Employees were exposed to fall hazards due to deficiencies with the scaffold such as but not limited to: scaffold platform was not at least 18 inches wide, stable object was not used to support scaffold platform, using ladder on scaffold to increase the working level, and not protected from falls by use of personal fall arrest systems or guardrail systems. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 VII |
Issuance Date | 2018-04-06 |
Abatement Due Date | 2018-04-12 |
Current Penalty | 3500.0 |
Initial Penalty | 5174.0 |
Final Order | 2018-04-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: a) Scaffold on the stairway between the fourth floor and the roof On or about 02/06/18, two employees were installing sheetrocks while standing on folded A-Frame ladders that was on a scaffold platform supported by a ladder and the step of stair. Employees are not protected from falls by the use of personal fall arrest systems or guardrail systems. Employees are exposed to falling approximately 12 feet to the fourth floor ground level. |
Citation ID | 01005A |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2018-04-06 |
Abatement Due Date | 2018-04-12 |
Current Penalty | 2375.0 |
Initial Penalty | 3696.0 |
Final Order | 2018-04-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Location: a) Scaffold on the stairway between the fourth floor and the roof On or about 02/06/18, employer did not have employees who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. |
Citation ID | 01005B |
Citaton Type | Serious |
Standard Cited | 19261060 A |
Issuance Date | 2018-04-06 |
Abatement Due Date | 2018-04-12 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-04-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would train each employee in the procedures to be followed to minimize hazards related to ladders and stairways. Location: a) Scaffold on the stairway between the fourth floor and the roof On or about 02/06/18, employer did not provide training to each employee who used a ladder that were exposed to a fall hazard to enable each employee to recognize the hazards related to ladders and the procedure to be followed in order to minimize these hazards. |
Citation ID | 01006 |
Citaton Type | Serious |
Standard Cited | 19261053 B04 |
Issuance Date | 2018-04-06 |
Abatement Due Date | 2018-04-12 |
Current Penalty | 3500.0 |
Initial Penalty | 5174.0 |
Final Order | 2018-04-24 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed. Location: a) Ladder on the stairway between the fourth floor and the roof On or about 02/06/18, two employees were installing sheetrocks while standing on folded A-Frame ladders that was on a scaffold platform supported by a ladder and the step of stair. Ladders were used for purposes other than the purposes for which they were designed: Used ladders as scaffold support, and used folded A-Frame ladders. Employees are exposed to falling approximately 12 feet to the fourth floor ground level. |