Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-02-28
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2017-03-10
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2017-03-01 |
Current Penalty |
1100.0 |
Initial Penalty |
2309.0 |
Final Order |
2017-03-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. a) On or about 02/15/17 at 231Hinchey Road, Rochester, New York; employee was working around the window on the second floor of a residential location on a ladder jack scaffold using the support ladder for access to the scaffold platform and was exposed to a 13 foot 9 inch fall. ABATEMENT DOCUMENTATION REQUIRED |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 |
Issuance Date |
2017-03-01 |
Current Penalty |
1209.0 |
Initial Penalty |
2309.0 |
Final Order |
2017-03-07 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1): Employees on scaffolds more than 10 feet (3.1 m) above a lower level were not protected from falling to that lower level by fall protection established in paragraphs (g)(1)(i)-(vii) of this section: a) On or about 02/15/17 at 231 Hinchey Road, Rochester, New York; employee was working around the window on the second floor of a residential location on a ladder jack scaffold without having any type of fall protection and was exposed to a 13 foot 9 inch fall. ABATEMENT DOCUMENTATION REQUIRED |
|
|