Search icon

STRUCTURE USA CORP

Company Details

Name: STRUCTURE USA CORP
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 28 Sep 2016 (9 years ago)
Entity Number: 5015998
ZIP code: 11211
County: Kings
Place of Formation: New York
Address: 183 WILSON ST #215, BROOKLYN, NY, United States, 11211

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
STRUCTURE USA CORP DOS Process Agent 183 WILSON ST #215, BROOKLYN, NY, United States, 11211

Permits

Number Date End date Type Address
X022022268A00 2022-09-25 2022-12-26 PLACE MATERIAL ON STREET EAGLE AVENUE, BRONX, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE
X022022268A04 2022-09-25 2022-10-06 PLACE EQUIPMENT OTHER THAN CRANE OR SHOV EAGLE AVENUE, BRONX, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE
X022022268A03 2022-09-25 2022-12-26 PLACE EQUIPMENT OTHER THAN CRANE OR SHOV EAGLE AVENUE, BRONX, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE
X022022268A02 2022-09-25 2022-12-26 OCCUPANCY OF SIDEWALK AS STIPULATED EAGLE AVENUE, BRONX, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE
X022022268A01 2022-09-25 2022-12-26 OCCUPANCY OF ROADWAY AS STIPULATED EAGLE AVENUE, BRONX, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE
X022022186A99 2022-07-05 2022-09-27 PLACE MATERIAL ON STREET EAGLE AVENUE, BRONX, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE
X022022186B00 2022-07-05 2022-09-27 OCCUPANCY OF ROADWAY AS STIPULATED EAGLE AVENUE, BRONX, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE
X022022186B01 2022-07-05 2022-09-27 OCCUPANCY OF SIDEWALK AS STIPULATED EAGLE AVENUE, BRONX, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE
X022022186B02 2022-07-05 2022-09-27 PLACE EQUIPMENT OTHER THAN CRANE OR SHOV EAGLE AVENUE, BRONX, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE
X022022186B03 2022-07-05 2022-09-27 PLACE EQUIPMENT OTHER THAN CRANE OR SHOV EAGLE AVENUE, BRONX, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE

History

Start date End date Type Value
2023-05-18 2025-04-03 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2023-05-08 2023-05-18 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2023-01-06 2023-05-08 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-07-15 2023-01-06 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-06-15 2022-07-15 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-04-04 2022-06-15 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-03-14 2022-04-04 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-02-12 2022-03-14 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2016-09-28 2022-02-12 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
160928010405 2016-09-28 CERTIFICATE OF INCORPORATION 2016-09-28

Inspections

Date Inspection Object Address Grade Type Institution Desctiption
2023-02-02 No data EAGLE AVENUE, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE No data Street Construction Inspections: Post-Audit Department of Transportation A/T/P/O I OBSERVED THE ABOVE RESPONDENT WITH JERSEY BARRIERS OBSTRUCTING THE SIDEWALK AND ROADWAY WITHOUT A VALID DEPARTMENT PERMIT. WAS ID BY EXPIRED PERMIT.
2022-09-26 No data EAGLE AVENUE, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE No data Street Construction Inspections: Active Department of Transportation Roadway occupancy in compliance.
2022-09-08 No data EAGLE AVENUE, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE No data Street Construction Inspections: Active Department of Transportation material on street cover with a tarp
2022-06-08 No data EAGLE AVENUE, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE No data Street Construction Inspections: Active Department of Transportation occupy r/w in compliance
2022-04-13 No data EAGLE AVENUE, FROM STREET EAST 149 STREET TO STREET TERRACE PLACE No data Street Construction Inspections: Active Department of Transportation I observed the above respondent with water filled barriers on the roadway without reflective markings capable of producing a warning glow when struck by the headlamps of a vehicle or other source of illuminations. Therefore NOV was issued .
2020-11-18 No data GERRY STREET, FROM STREET HARRISON AVENUE TO STREET THROOP AVENUE No data Street Construction Inspections: Pick-Up Department of Transportation Upon arrival respondent STRUCTURE USA CORP failed to obtain a valid DOT permit on file for the movement/use of the crane. Nov issued called engineer STEVE at phone#718-701-2707 at 10:15AM on 11-17-2020 asked him to obtain DOT permit Repeated offender
2020-11-17 No data GERRY STREET, FROM STREET HARRISON AVENUE TO STREET THROOP AVENUE No data Street Construction Inspections: Pick-Up Department of Transportation Upon arrival respondent STRUCTURE USA CORP failed to obtain a valid DOT permit on file for the movement/use of the crane. Nov issued called engineer STEVE at phone # 718-701-2707 at 10:15AM on 11-17-2020 asked him to obtain DOT permit
2020-08-04 No data GERRY STREET, FROM STREET HARRISON AVENUE TO STREET THROOP AVENUE No data Street Construction Inspections: Active Department of Transportation In parking lane ok.
2020-07-10 No data GERRY STREET, FROM STREET HARRISON AVENUE TO STREET THROOP AVENUE No data Street Construction Inspections: Active Department of Transportation ped/ walk not visible
2020-07-09 No data GERRY STREET, FROM STREET HARRISON AVENUE TO STREET THROOP AVENUE No data Street Construction Inspections: Active Department of Transportation material not visible

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345839864 0215000 2022-03-17 2250 59TH STREET, BROOKLYN, NY, 11204
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2022-03-17
Case Closed 2022-08-22

Related Activity

Type Inspection
Activity Nr 1430657
Safety Yes
344659438 0215000 2020-02-27 2109 REGENT PLACE, BROOKLYN, NY, 11226
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2020-02-27
Emphasis L: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1465947
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260416 E01
Issuance Date 2020-06-01
Current Penalty 5398.0
Initial Penalty 5398.0
Final Order 2020-07-10
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.416(e)(1): Worn or frayed electric cords or cables were used Location: a) 4th floor to roof a) On or about 02/27/2020, an employee used a corded Makita Shear Bolt Wrench to tighten and cut/shear the bolts. The cord of the tool was frayed.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260760 A01
Issuance Date 2020-06-01
Current Penalty 9446.0
Initial Penalty 9446.0
Final Order 2020-07-10
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.760(a)(1): Each employee engaged in a steel erection activity who is on a walking/working surface with an unprotected side or edge more than 15 feet (4.6 m) above a lower level was not protected from fall hazards by guardrail systems, safety net systems, personal fall arrest systems, positioning device systems, or fall restraint systems. Location: a) Roof of 4th floor; on C-joist and Steel beams a) On or about 02/27/2020, an employee did not use fall protection when he sat on the C-joist/beams of the roof to tighten and shear the bolts.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2020-06-01
Current Penalty 5398.0
Initial Penalty 5398.0
Final Order 2020-07-10
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided Location: a) 4th floor stairway landing; last landing leading to roof a) On or about 02/27/2020, an employee climbed framework/beams of the wall and jumped down onto the stairway landing as a means of access to and from the 4th floor mezzanine area.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2020-06-01
Current Penalty 6747.0
Initial Penalty 6747.0
Final Order 2020-07-10
Nr Instances 2
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed Location: a) 4th floor to 4th floor mezzanine. 4th floor mezzanine to roof (C-joist) a) On or about 02/27/2020, employees used an 8 feet and a 6 feet A-frame ladder as access to the 4th floor mezzanine and roof. The ladders did not reach the intended landing surface being accessed.
344306576 0215000 2019-09-13 2250 59TH STREET, BROOKLYN, NY, 11204
Inspection Type Prog Related
Scope Partial
Safety/Health Safety
Close Conference 2019-09-13
Emphasis L: LOCALTARG, P: LOCALTARG
Case Closed 2024-12-18

Related Activity

Type Referral
Activity Nr 1430646
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2019-11-21
Abatement Due Date 2019-12-11
Current Penalty 5304.0
Initial Penalty 5304.0
Final Order 2019-12-19
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met. As reference in 29 CFR 1926.59. Location: a) At 2250 59th Street, Brooklyn, NY 11204: On or about 09/12/2019, employees were pouring concrete through a pneumatic hose, were exposed to chemical hazards from concrete. The employer did not develop and implement a written hazard communication program.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19101200 G01
Issuance Date 2019-11-21
Abatement Due Date 2019-12-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-19
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(1): Employers did not have a safety data sheet in the workplace for each hazardous chemical which they use. As reference in 29 CFR 1926.59. Location: a) At 2250 59th Street, Brooklyn, NY 11204: On or about 09/12/2019, employees were pouring concrete through a pneumatic hose, were exposed to chemical hazards from concrete. The employer did not have safety data sheets (SDS) for chemicals used at the site.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2019-11-21
Abatement Due Date 2019-12-11
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-19
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area. As reference in 29 CFR 1926.59. Location: a) At 2250 59th Street, Brooklyn, NY 11204: On or about 09/12/2019, employees were pouring concrete through a pneumatic hose, were exposed to chemical hazards from concrete. The employer did not provide training on the hazards associated to the chemicals used at the site.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260095 A
Issuance Date 2019-11-21
Abatement Due Date 2019-12-04
Current Penalty 5304.0
Initial Penalty 5304.0
Final Order 2019-12-19
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact. Location: a) At 2250 59th Street, Brooklyn, NY 11204: On or about 09/12/2019, employees were pouring concrete through a pneumatic hose in the jobsite without personal protective equipment for face and hand, and were exposed to chemical burns from not being protected by effective personal protective equipment.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260701 F
Issuance Date 2019-11-21
Abatement Due Date 2019-12-04
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-12-19
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.701(f): Employee(s) were applying a cement, sand, and water mixture through a pneumatic hose and were not wearing protective head and face equipment. Location: a) At 2250 59th Street, Brooklyn, NY 11204: On or about 09/12/2019, employees were pouring concrete through a pneumatic hose in the jobsite without personal protective equipment for face, and were exposed to chemical burns.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260201 A
Issuance Date 2019-11-21
Abatement Due Date 2019-11-27
Current Penalty 6630.0
Initial Penalty 6630.0
Final Order 2019-12-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.201(a) / MUTCD Section 6E.02: Signaling by flaggers and the use of flaggers, including warning garments worn by flaggers did not conform to Part VI of the Manual on Uniform Traffic Control Devices for Streets and Highways (MUTCD), 2009 Edition, December 2009 (including Revision 1 dated May 2012 and Revision 2 dated May 2012), in that for daytime and nighttime activity, flaggers shall wear high-visibility safety apparels that meets the Performance Class 2 or 3 requirements of the ANSI/ISEA 107-20004 publication. Location: a) On the northeast exterior of the jobsite at 2250 59th Street, Brooklyn, NY 11204: On or about 09/12/2019, a flagger did not wear a high-visibility safety apparel, and was exposed to struck by hazard.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2019-11-21
Current Penalty 6630.0
Initial Penalty 6630.0
Final Order 2019-12-19
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous Location: a) At 2250 59th Street, Brooklyn, NY 11204: On or about 09/13/2019, employees used an extension cord to energize electrical equipment. The path to ground was not continuous because the ground pin of the extension cord was missing.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260501 B04 I
Issuance Date 2019-11-21
Current Penalty 6630.0
Initial Penalty 6630.0
Final Order 2019-12-19
Nr Instances 1
Nr Exposed 8
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights), more than six feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around such holes. Location: a) At 2250 59th Street, Brooklyn, NY 11204: On or about 09/12/2019, employees on the jobsite used a stairway to access the cellar level of the jobsite. The employee had to walk over a hole between the ground level and the stair top step to access the stairway. The employees were exposed to falling approximately 12 feet to the lower level. The employees were not protected by the use of guardrails, covers, or personal fall arrest systems.

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
3301527 Intrastate Non-Hazmat 2019-06-19 - - 1 1 Private(Property)
Legal Name STRUCTURE USA CORP
DBA Name -
Physical Address 183 WILSON AVE , BROOKLYN, NY, 11237, US
Mailing Address 183 WILSON AVE , BROOKLYN, NY, 11237, US
Phone (646) 339-1277
Fax -
E-mail HERSHYGRUNBLATT@GMAIL.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 24 Mar 2025

Sources: New York Secretary of State