Name: | SS ALAM CONSTRUCTION CORP |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Inactive |
Date of registration: | 13 Oct 2016 (9 years ago) |
Date of dissolution: | 09 Mar 2020 |
Entity Number: | 5023117 |
ZIP code: | 11218 |
County: | Kings |
Place of Formation: | New York |
Address: | 392 EAST 3RD ST FL 1, BROOKLYN, NY, United States, 11218 |
Principal Address: | 392 E 3RD ST,, 1ST FL., BROOKLYN, NY, United States, 11218 |
Contact Details
Phone +1 917-573-6718
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
MOHAMMED ALAM | Chief Executive Officer | 392 E 3RD ST, 1ST FL, BROOKLYN, NY, United States, 11218 |
Name | Role | Address |
---|---|---|
SS ALAM CONSTRUCTION CORP | DOS Process Agent | 392 EAST 3RD ST FL 1, BROOKLYN, NY, United States, 11218 |
Number | Status | Type | Date | End date |
---|---|---|---|---|
2047427-DCA | Inactive | Business | 2017-01-17 | 2021-02-28 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
200309000116 | 2020-03-09 | CERTIFICATE OF DISSOLUTION | 2020-03-09 |
190815060395 | 2019-08-15 | BIENNIAL STATEMENT | 2018-10-01 |
161013010443 | 2016-10-13 | CERTIFICATE OF INCORPORATION | 2016-10-13 |
Fee Sequence Id | Fee type | Status | Date | Amount | Description |
---|---|---|---|---|---|
2912234 | TRUSTFUNDHIC | INVOICED | 2018-10-18 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2912235 | RENEWAL | INVOICED | 2018-10-18 | 100 | Home Improvement Contractor License Renewal Fee |
2533725 | TRUSTFUNDHIC | INVOICED | 2017-01-17 | 200 | Home Improvement Contractor Trust Fund Enrollment Fee |
2533766 | BLUEDOT | INVOICED | 2017-01-17 | 100 | Bluedot Fee |
2533724 | LICENSE | INVOICED | 2017-01-17 | 25 | Home Improvement Contractor License Fee |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
342409208 | 0215000 | 2017-06-18 | 1382 NOSTRAND AVENUE, BROOKLYN, NY, 11226 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Accident |
Activity Nr | 1229682 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260020 B02 |
Issuance Date | 2017-12-15 |
Abatement Due Date | 2017-12-21 |
Current Penalty | 2853.75 |
Initial Penalty | 3803.0 |
Contest Date | 2018-01-16 |
Final Order | 2018-06-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.20(b)(2): The employer did not initiate and maintain programs which provided for frequent and regular inspections of the job site, materials and equipment to be made by a competent person(s) Location: 1382 Nostrand Avenue, Brooklyn. a) The employer did not implement a program for frequent and regular inspections of the job site and equipment being used by the employee. On or about 06/18/2017. |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19260451 D03 IX |
Issuance Date | 2017-12-15 |
Abatement Due Date | 2017-12-28 |
Current Penalty | 2037.0 |
Initial Penalty | 2716.0 |
Contest Date | 2018-01-16 |
Final Order | 2018-06-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(d)(3)(ix): Tiebacks were not secured to a structurally sound anchorage on the building or structure: location: 1382 Nostrand Avenue, Brooklyn, NY. a) Tiebacks for the 2 point suspended scaffold were secured to communication cables, satellite dish and a chimney. On or about 06/18/2017. |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19260451 D03 X |
Issuance Date | 2017-12-15 |
Abatement Due Date | 2017-12-28 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Contest Date | 2018-01-16 |
Final Order | 2018-06-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(d)(3)(x): Tiebacks were not installed perpendicular to the face of the building or structure, nor were opposing angle tiebacks installed: location: 1382 Nostrand Avenue, Brooklyn, NY. a) Tiebacks for the 2 point suspended scaffold were not installed perpendicular nor at opposing angles to the face of the building. On or about 06/18/2017. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 F07 |
Issuance Date | 2017-12-15 |
Abatement Due Date | 2017-12-21 |
Current Penalty | 2852.25 |
Initial Penalty | 3803.0 |
Contest Date | 2018-01-16 |
Final Order | 2018-06-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(f)(7): Scaffolds were not erected, moved, dismantled, or altered, by trained and experienced employees under the supervision and direction of a competent person qualified in scaffold erection, moving, dismantling or alteration:; Such activities were not performed only by experienced and trained employees selected for such work by the competent person. Location: 1382 Nostrand Avenue, Brooklyn. a) The two point suspended scaffold was not erected and dismantled under the supervision of a competent person. The scaffold tilted and an employee fell 4 stories. On or about 06/18/2017. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 II |
Issuance Date | 2017-12-15 |
Abatement Due Date | 2017-12-21 |
Current Penalty | 9506.84 |
Initial Penalty | 12675.0 |
Contest Date | 2018-01-16 |
Final Order | 2018-06-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Related Event Code (REC) | Accident |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(ii): Each employee on a single-point or two-point adjustable suspension scaffold was not protected by both a personal fall arrest system and a guardrail system: Location: 1382 Nostrand Avenue, Brooklyn. a) An employee was working on a manual operated two point suspended scaffold and he did not utilizing a complete fall protection system. The scaffold went vertical and an employee fell 4 stories. On or about 06/18/2017. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19260454 A |
Issuance Date | 2017-12-15 |
Abatement Due Date | 2017-12-28 |
Current Penalty | 2037.0 |
Initial Penalty | 2716.0 |
Contest Date | 2018-01-16 |
Final Order | 2018-06-25 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.454(a): The employer shall have each employee who performs work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Location: 1382 Nostrand Avenue, Brooklyn, NY An employee was not trained in the recognition and elimination of hazards associated with the two point suspended scaffold he was working from. On or about 06/18/2017. |
Date of last update: 24 Mar 2025
Sources: New York Secretary of State