Inspection Type |
Referral
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-10-30
|
Emphasis |
L: FALL
|
Case Closed |
2018-08-15
|
Related Activity
Type |
Referral |
Activity Nr |
1279359 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 II |
Issuance Date |
2017-11-15 |
Abatement Due Date |
2018-09-10 |
Current Penalty |
2471.95 |
Initial Penalty |
3803.0 |
Contest Date |
2017-12-05 |
Final Order |
2018-08-10 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) 10 Mill Lane, Schenectady, First Floor Rehab & Ground Floor, on October 30, 2017, and at times prior, ground-fault circuit interrupter was not provided for receptacles used to power portable electric tools. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260405 A01 I |
Issuance Date |
2017-11-15 |
Abatement Due Date |
2018-09-10 |
Current Penalty |
1412.45 |
Initial Penalty |
2173.0 |
Contest Date |
2017-12-05 |
Final Order |
2018-08-10 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(a)(1)(i): Metal raceways, cable armor, and other metal enclosures for conductors were not metallically joined together into a continuous electric conductor and so connected to all boxes, fittings, and cabinets as to provide effective electrical continuity: a) 10 Mill Lane, Schenectady, first Floor Rehab, on October 30, 2017, and at times prior, conduit for the feeder circuit did not extend from the ceiling to the temporary circuit breaker panel box. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2017-11-15 |
Abatement Due Date |
2018-09-10 |
Current Penalty |
2471.95 |
Initial Penalty |
3803.0 |
Contest Date |
2017-12-05 |
Final Order |
2018-08-10 |
Nr Instances |
2 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) 10 Mill Lane, Schenectady, on October 30, 2017, and at times prior, the employer established a walk way with an unprotected edge exposing employees to a 12 foot fall hazard. |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19260501 B04 II |
Issuance Date |
2017-11-15 |
Abatement Due Date |
2018-09-10 |
Current Penalty |
198.25 |
Initial Penalty |
305.0 |
Contest Date |
2017-12-05 |
Final Order |
2018-08-10 |
Nr Instances |
4 |
Nr Exposed |
4 |
Related Event Code (REC) |
Complaint |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(ii): Each employee on a walking/working surface was not protected from tripping in or stepping into or through holes (including skylights) by covers: a) 10 Mill Lane, Schenectady, First Floor Rehab, on October 30, 2017, and at times prior, several large holes in the floor were not guarded, exposing employees to trip hazards. |
|
|