Name: | SPARTAN MASONRY CONSTRUCTION INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 03 Feb 2017 (8 years ago) |
Entity Number: | 5079577 |
ZIP code: | 11228 |
County: | Orange |
Place of Formation: | New York |
Address: | 7014 13TH AVENUE SUITE 202, BROOKLYN, NY, United States, 11228 |
Shares Details
Shares issued 100
Share Par Value 0.001
Type PAR VALUE
Name | Role | Address |
---|---|---|
UNITED STATES CORPORATION AGENTS, INC. | Agent | 7014 13TH AVENUE SUITE 202, BROOKLYN, NY, 11228 |
Name | Role | Address |
---|---|---|
C/O UNITED STATES CORPORATION AGENTS, INC. | DOS Process Agent | 7014 13TH AVENUE SUITE 202, BROOKLYN, NY, United States, 11228 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
170203000260 | 2017-02-03 | CERTIFICATE OF INCORPORATION | 2017-02-03 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
343070793 | 0216000 | 2018-04-06 | 111 EAST 172ND ST., BRONX, NY, 10452 | |||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1267452 |
Safety | Yes |
Inspection Type | Prog Related |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2017-10-02 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2018-04-11 |
Related Activity
Type | Inspection |
Activity Nr | 1255158 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 G02 |
Issuance Date | 2017-10-04 |
Abatement Due Date | 2017-10-17 |
Current Penalty | 8873.0 |
Initial Penalty | 8873.0 |
Final Order | 2017-11-01 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(2): The employer did not provide fall protection for employees erecting or dismantling supported scaffolds: location: exterior of 7th floor, east elevation Employees, erecting a tubular welded frame scaffold, were not provided with fall protection. The employees were exposed to a fall of up to 60 feet. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |