Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347696858 | 0215800 | 2024-08-20 | 201 WAVEL STREET, SYRACUSE, NY, 13206 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
346486384 | 0215800 | 2023-02-07 | 201 WAVEL STREET, SYRACUSE, NY, 13206 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
342920386 | 0215800 | 2018-02-01 | EMPOWER FEDERAL CREDIT UNION, 900 KINNE STREET, EAST SYRACUSE, NY, 13057 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19260304 F |
Issuance Date | 2018-02-22 |
Abatement Due Date | 2018-03-05 |
Current Penalty | 1800.0 |
Initial Penalty | 2772.0 |
Final Order | 2018-03-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) Main Lobby, on or about 2-1-18: Two employees were ripping ¾ inch pine boards and wood trim pieces on a table saw that was not equipped with a spreader. b) Main Lobby, on or about 2-1-18: Two employees were ripping ¾ inch pine boards and wood trim pieces on a table saw that was not equipped with non kick-back fingers or "dogs". c) Main Lobby, on or about 2-1-18: Two employees were ripping ¾ inch pine boards and wood trim pieces on a table saw that was not equipped with a magnetic switch or anti-restart device. ABATEMENT CERTIFICATION IS REQUIRED FOR THE ABOVE ITEMS |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19260304 I01 |
Issuance Date | 2018-02-22 |
Abatement Due Date | 2018-03-05 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2018-03-21 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) Main Lobby, on or about 2-1-18: Two employees were ripping ¾ inch pine boards and wood trim pieces on a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |