Search icon

EMUNAH CONSTRUCTION CORP

Company Details

Name: EMUNAH CONSTRUCTION CORP
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 02 Mar 2017 (8 years ago)
Entity Number: 5094884
ZIP code: 11798
County: Suffolk
Place of Formation: New York
Address: 21 LINDSAY AVE, WYANDANCH, NY, United States, 11798

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 21 LINDSAY AVE, WYANDANCH, NY, United States, 11798

Filings

Filing Number Date Filed Type Effective Date
170302010197 2017-03-02 CERTIFICATE OF INCORPORATION 2017-03-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342290301 0214700 2017-05-01 22 HARMONY LANE, WESTBURY, NY, 11590
Inspection Type Fat/Cat
Scope Complete
Safety/Health Safety
Close Conference 2017-05-01
Emphasis L: FALL

Related Activity

Type Accident
Activity Nr 1207199
Type Inspection
Activity Nr 1229909
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2017-10-27
Abatement Due Date 2017-11-02
Current Penalty 3421.0
Initial Penalty 3803.0
Final Order 2018-01-16
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite (Exterior, Front of Building) - 22 Harmony Lane, Westbury, NY: Employees working directly under ongoing sheathing and joisting activities were not provided with head protection, exposing them to struck by hazards from tools and materials; on or about 5/1/17. b) Worksite (Interior) - 22 Harmony Lane, Westbury, NY: Employees working directly under ongoing sheathing and joisting activities were not provided with head protection, exposing them to struck by hazards from tools and materials; on or about 5/1/17. Abatement documentation is required for this item in accordance with 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2017-10-27
Abatement Due Date 2017-11-02
Current Penalty 3421.0
Initial Penalty 3803.0
Final Order 2018-01-16
Nr Instances 1
Nr Exposed 5
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Worksite - 22 Harmony Lane, Westbury, NY: Employees performing framing work using Hitachi NV 83A4 3.25 Coil Nailer (Pneumatic) were not provided with safety glasses. Employees were exposed to struck by hazards from flying particles; on or about 5/1/17. Abatement documentation is required for this item in accordance with 29 CFR 1903.19.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19261053 B05 I
Issuance Date 2017-10-27
Abatement Due Date 2017-11-02
Current Penalty 11410.0
Initial Penalty 12675.0
Final Order 2018-01-16
Nr Instances 2
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(5)(i): Non-self-supporting ladders were not used at an angle such than the horizontal distance from the top support to the foot of the ladder way approximately one-quarter of the working length of the ladder (the distance along the ladder between the foot and the top support): a) Worksite (Front Exterior) - 22 Harmony Lane, Westbury, NY: An employee was working from a 40 ft. Werner Portable Extension Ladder that was set up at approximately 17 ft. high and extended approximately 8 ft. away from the house. The horizontal distance from the top support to the foot of the ladder was approximately one-half of the working length of the ladder, exposing employees to fall hazards; on or about 5/1/17. b) Worksite (Front Exterior) - 22 Harmony Lane, Westbury, NY: An employee was working from a 24 ft. Werner Portable Extension Ladder that was set up at approximately 13 ft. high and extended approximately 6 ft. 10 in. away from the house. The horizontal distance from the top support to the foot of the ladder was approximately one-half of the working length of the ladder, exposing employees to fall hazards; on or about 5/1/17. Abatement documentation required for this item in accordance with 29 CFR 1903.19.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19261060 A
Issuance Date 2017-10-27
Abatement Due Date 2017-11-16
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2018-01-16
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1060(a): The employer did not provide a training program for each employee using ladders and stairways, as necessary, which would enable each employee to recognize hazards related to ladders and stairways and train each employee in the procedures to be followed to minimize these hazards: a) Worksite (Exterior) - 22 Harmony Lane, Westbury, NY: Employees working from portable extension ladders performing tasks including, but not limited to, sheathing work were not provided with a training program which would enable the employees to recognize hazards related to ladders and train employees in the procedures to be followed to minimize these hazards. Employees were working from improperly set up ladders; on or about 5/1/17. Abatement documentation is required for this item in accordance with 29 CFR 1903.19.
106817539 0213100 1989-10-19 ROUTE 3, DANNEMORA, NY, 12921
Inspection Type Planned
Scope NoInspection
Safety/Health Safety
Close Conference 1989-10-19
Case Closed 1989-10-27

Date of last update: 24 Mar 2025