OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344384748 0215000 2019-10-17 870 7TH AVENUE, NEW YORK, NY, 10019
Inspection Type Unprog Rel
Scope Partial
Safety/Health Safety
Close Conference 2019-10-17
Emphasis L: FALL, P: FALL
Case Closed 2021-10-18

Related Activity

Type Complaint
Activity Nr 1509168
Safety Yes
Type Inspection
Activity Nr 1438501
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2020-03-19
Current Penalty 1500.0
Initial Penalty 3084.0
Final Order 2020-04-01
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units. Location: Top of Canopy above main entrance of building a) On or about 10/17/2019, an employee was working from on top of a stack of wooden planks which was placed across crates. the employee was painting a column.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2020-03-19
Current Penalty 3522.0
Initial Penalty 5398.0
Final Order 2020-04-01
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. Location: Permanent horizontal platform between top of sidewalk shed and top of main entrance canopy a) On or about 10/17/2019, employees walking between the top of the sidewalk shed and the top of the main entrance canopy exposed to fall of approximately 10 feet.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2020-03-19
Current Penalty 2456.0
Initial Penalty 4626.0
Final Order 2020-04-01
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairways or ladders were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, and no ramp, runway, sloped embankment, or personnel hoist was provided. Location: Sidewalk to the top of sidewalk shed a) On or about 10/17/2019, there was a break in elevation of 27 inches from an extension ladder to the sidewalk shed. Employees used the ladder to access the shed platform.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2020-03-19
Current Penalty 3522.0
Initial Penalty 5398.0
Final Order 2020-04-01
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): The ladder extension was positioned such that deflection under a load, by itself, would cause the ladder to slip off its support. Location: Top of sidewalk shed to the working platform of the set-back area a) On or about 10/17/2019, employees used an extension ladder to access the working platform on the set-back of the building. The ladder slid left while the employee was climbing up the ladder.