Inspection Type |
Complaint
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2017-10-25
|
Emphasis |
L: FALL
|
Case Closed |
2023-07-10
|
Related Activity
Type |
Complaint |
Activity Nr |
1277960 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1274877 |
Health |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2018-03-12 |
Current Penalty |
2772.0 |
Initial Penalty |
2772.0 |
Final Order |
2018-05-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): 1) On or about 10/25/2017, at the site of 183-41 Grand Central Parkway, Jamaica, NY Employees repairing a leakage on a pitch roof was exposed to the hazard of falling approximately 30 ft. to the ground below. ABATEMENT VERIFICATION IS NOT REQUIRED PURSUANT TO 29 CFR 1903.19. |
|
|
Inspection Type |
Unprog Rel
|
Scope |
Partial
|
Safety/Health |
Health
|
Close Conference |
2017-10-25
|
Case Closed |
2024-03-25
|
Related Activity
Type |
Complaint |
Activity Nr |
1277960 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1272886 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19101200 E01 |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-26 |
Current Penalty |
1663.0 |
Initial Penalty |
1663.0 |
Final Order |
2018-05-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) (a) On or about October 25, 2017, at 183-41 Grand Central Parkway, Jamaica, NY 11432 Employer had not developed a written hazard communication program to cover employee use on site of hazardous chemicals such as gasoline (contains benzene, butane, toluene, xyelenes, ethylbenzene etc.; highly flammable liquid and vapor, irritant, contains carcinogens) and Great Stuff Big Gap Filler Insulating Foam Sealant (contains diisocyanates; extremely flammable, respirator and skin sensitizer and irritant). ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19101200 G08 |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-03-22 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-05-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical, and did not ensure that they were readily accessible during each work shift to employees when they were in their work area(s): (Construction Reference: 1926.59) (a) On or about October 25, 2017, at 183-41 Grand Central Parkway, Jamaica, NY 11432 Employer had not obtained or provided access to safety data sheets for employees who were using azardous chemicals such as gasoline (contains benzene, butane, toluene, xyelenes, ethylbenzene etc.; highly flammable liquid and vapor, irritant, contains carcinogens) and Great Stuff Big Gap Filler Insulating Foam Sealant (contains diisocyanates; extremely flammable, respirator and skin sensitizer and irritant). ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
01001C |
Citaton Type |
Serious |
Standard Cited |
19101200 H01 |
Issuance Date |
2018-03-12 |
Abatement Due Date |
2018-04-26 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2018-05-01 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) (a) On or about October 25, 2017, at 183-41 Grand Central Parkway, Jamaica, NY 11432 Employer had not provided hazard communication program to employees who used hazardous chemicals such as gasoline (contains benzene, butane, toluene, xyelenes, ethylbenzene etc.; highly flammable liquid and vapor, irritant, contains carcinogens) and Great Stuff Big Gap Filler Insulating Foam Sealant (contains diisocyanates; extremely flammable, respirator and skin sensitizer and irritant). ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
Citation ID |
02001 |
Citaton Type |
Other |
Standard Cited |
19030019 C01 |
Issuance Date |
2019-01-16 |
Abatement Due Date |
2019-02-05 |
Current Penalty |
1000.0 |
Initial Penalty |
1000.0 |
Final Order |
2019-03-26 |
Nr Instances |
1 |
Nr Exposed |
3 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1903.19(c)(1): The employer failed to certify to OSHA (the Agency) that each cited violation has been abated: On or about August 2nd, 2018, at 183-41 Grand Central Parkway, Jamaica, NY, 11432 The employer failed to certify abatement required for Citation 1, Items 1a, 1b, and 1c. Abatement certification for these items were due on 04/26/2018, 03/22/2018, and 04/26/2018 respectively. ABATEMENT CERTIFICATION REQUIRED PURSUANT TO 29 CFR 1903.19 |
|
|