Search icon

ATMOSPHERE BUILDING SOLUTIONS BY SERGIO A. ORTIZ INC.

Company Details

Name: ATMOSPHERE BUILDING SOLUTIONS BY SERGIO A. ORTIZ INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 25 Apr 2017 (8 years ago)
Entity Number: 5125277
ZIP code: 11367
County: Queens
Place of Formation: New York
Address: 71-1 Park Dr East, Apt 1-L, Flushing, NY, United States, 11367

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
YULI C.BRAN Chief Executive Officer 71-1 PARK DR EAST, APT 1-L, FLUSHING, NY, United States, 11367

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 71-1 Park Dr East, Apt 1-L, Flushing, NY, United States, 11367

History

Start date End date Type Value
2017-04-25 2022-09-30 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
211027003264 2021-10-27 BIENNIAL STATEMENT 2021-10-27
170425010162 2017-04-25 CERTIFICATE OF INCORPORATION 2017-04-25

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344553037 0215600 2020-01-10 112-16 ASTORIA BLVD, ASTORIA, NY, 11106
Inspection Type Unprog Rel
Scope Partial
Safety/Health Health
Close Conference 2020-01-10
Case Closed 2024-09-30

Related Activity

Type Inspection
Activity Nr 1455383
Health Yes
Type Inspection
Activity Nr 1455122
Safety Yes
Type Inspection
Activity Nr 1455106
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2020-03-25
Abatement Due Date 2020-04-20
Current Penalty 2313.0
Initial Penalty 2313.0
Final Order 2020-07-08
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(e)(1): The employer did not develop, implement, and/or maintain at the workplace a written hazard communication program which describes how the criteria specified in 29 CFR 1910.1200(f), (g), and (h) will be met: (Construction Reference: 1926.59) a)Worksite: Employees were exposed to hazardous chemicals such as but not limited to, silica sand (50lbs bags), DOWSIL ALLGUARD 1200 OS Primer Red (containing, Octamethyltrisiloxana a category 3 flammable liquid), and DOWSIL ALLGUARD Silicone Elastomeric Coating Deep Tint Base (contains, limestone or calcium carbonate a skin sensitizer) while working to waterproof the surface of a newly constructed cement roof. The employer had not develop a hazard communication program; on or about 1/10/2020. ABATEMENT NOTE: The written Hazard Communication Program must include descriptions of how the following program elements, required by this regulation, will be developed, implemented, and conveyed to the employer's employee(s) who are exposed to hazardous materials: a. Labeling and other forms or warning: Labels shall include at least the identity of the hazardous chemical(s), the appropriate hazard warnings, the target organs, and the name and address of the chemical manufacturer, importer or other responsible party; b. A list or inventory of all hazardous materials known to be present in the workplace must be compiled and be maintained as part of the employer's written Hazard Communication Program; c. Safety Data Sheets (SDSs) for all materials used by employee(s) in the workplace must be maintained and readily available all employee(s) on all shifts. d. The employer's Hazardous Materials Information and Training Program must be based upon the employer's written Hazard Communication Program. The training for employee(s) must include at least: Methods and observation that may be used to detect the presence or release of hazardous chemicals in the work area. The physical and health hazards of the chemicals in the work area. The measures employee(s) can take to protect themselves, such as, specific procedures, appropriate work practices, emergency procedures, and personal protective equipment to be used. The details of the employer's Hazard Communication Program including an explanation of the labeling systems used, Safety Data Sheets and how employees can obtain and use the appropriate hazard information; e. Methods used to inform employees of the hazards associated with non routine tasks must also be addressed in the employer's written program; and f. The employer's written Hazard Communication Program must be made available upon request. For Multi Employer Work places, the employer's Written Hazard Communication Program must also specifically address how: a. Safety Data Sheets for each hazardous material on the job site will be provided to other employers in the event the other employer's employee(s) may be exposed to these materials. b. The methods the employer will use to inform other employer(s) of any precautionary measures that need to be taken to protect employee(s) during normal operating conditions and in foreseeable emergencies. c. The methods the employer will use to inform the other employer(s) of the labeling system used in the workplace.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19101200 G08
Issuance Date 2020-03-25
Abatement Due Date 2020-04-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-07-08
Nr Instances 1
Nr Exposed 7
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(g)(8): The employer did not maintain in the workplace copies of the required safety data sheets for each hazardous chemical a. Worksite: Employees working with hazardous chemicals such as but not limited to, silica sand (50lbs bag), DOWSIL ALLGUARD 1200 OS Primer Red (containing, Octamethyltrisiloxana a category 3 flammable liquid), and DOWSIL ALLGUARD Silicone Elastomeric Coating Deep Tint Base (contains, limestone or calcium carbonate a skin sensitizer) while waterproofing the surface of a roof. Safety data sheets were not made available; on or about 1/10/2020. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2020-03-25
Abatement Due Date 2020-04-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-07-08
Nr Instances 1
Nr Exposed 7
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: (Construction Reference: 1926.59) a) Worksite: Employees were exposed to hazardous chemicals such as but not limited to, Silica Sand (50lbs bag), DOWSIL ALLGUARD 1200 OS Primer Red (containing, Octamethyltrisiloxana a category 3 flammable liquid), and DOWSIL ALLGUARD Silicone Elastomeric Coating Deep Tint Base (contains, limestone or calcium carbonate a skin sensitizer) while working to waterproof the surface of a roof for a new construction project (Marriott Hotel 7-story high-rise). A training program for hazard communication was not in place; on or about 1/10/2020. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 02001
Citaton Type Other
Standard Cited 19100134 C02 I
Issuance Date 2020-03-25
Abatement Due Date 2020-04-20
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-07-08
Nr Instances 1
Nr Exposed 7
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(2)(i): Respirator users were not provided with the information contained in Appendix D to 29 CFR 1910.134 when the employer determined that any voluntary respirator use was permissible: (Construction Reference 1926.103) a)Worksite: Employees were exposed inhalation hazards while wearing a filtering face-piece respirator such as an N95 mask. Employees were using chemicals such as but not limited to, , silica sand (50lbs bag), DOWSIL ALLGUARD 1200 OS Primer Red (containing, Octamethyltrisiloxana a category 3 flammable liquid), and DOWSIL ALLGUARD Silicone Elastomeric Coating Deep Tint Base (contains, limestone or calcium carbonate a skin sensitizer) in order to waterproof the surface of a roof. Appendix D from OSHA's 29 CFR 1910.134 was not provided to the employees.