Name: | USA MEX CONCRETE MASONRY, INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 15 May 2017 (8 years ago) |
Entity Number: | 5137139 |
ZIP code: | 11369 |
County: | Queens |
Place of Formation: | New York |
Address: | 105-05 DITMARS BLVD, EAST ELMHURST, NY, United States, 11369 |
Shares Details
Shares issued 200
Share Par Value 0
Type NO PAR VALUE
Name | Role | Address |
---|---|---|
USA MEX CONCRETE MASONRY, INC. | DOS Process Agent | 105-05 DITMARS BLVD, EAST ELMHURST, NY, United States, 11369 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
170515010349 | 2017-05-15 | CERTIFICATE OF INCORPORATION | 2017-05-15 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345449250 | 0216000 | 2021-06-23 | 5726 POST RD., BRONX, NY, 10471 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1537847 |
Health | Yes |
Type | Inspection |
Activity Nr | 1542409 |
Safety | Yes |
Violation Items
Citation ID | 01001A |
Citaton Type | Serious |
Standard Cited | 19261153 C01 |
Issuance Date | 2021-08-31 |
Abatement Due Date | 2021-09-20 |
Current Penalty | 2926.0 |
Initial Penalty | 2926.0 |
Final Order | 2021-11-23 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1153(c)(1): For each employee engaged in a task identified on Table 1, the employer did not fully and properly implement the engineering controls, work practices, and respiratory protection specified for the task on Table 1, unless the employer assesses and limits the exposure of the employee to respirable crystalline silica in accordance with paragraph (d) of this section. a) Jobsite, 5726 Post Rd. Bronx, NY 10471 Employees were cutting cinder block and red brick using a Makita angle grinder without implementing engineering controls, work practices ; on or about 6/16/21. |
Citation ID | 01001B |
Citaton Type | Serious |
Standard Cited | 19261153 G01 |
Issuance Date | 2021-08-31 |
Abatement Due Date | 2021-09-20 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2021-11-23 |
Nr Instances | 1 |
Nr Exposed | 4 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1153(g)(1):The employer did not establish and implement a written exposure control plan: a) Jobsite, 5726 Post Rd. Bronx, NY 10471 Employees were cutting cinder block and red brick using a Makita angle grinder without implementing engineering controls, work practices. The employer did not establish or implement a written Silica exposure control plan; on or about 6/16/21. |
Inspection Type | Referral |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2021-06-16 |
Emphasis | L: FALL, N: RCS-NEP |
Related Activity
Type | Referral |
Activity Nr | 1785879 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1536649 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1544925 |
Health | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260300 B01 |
Issuance Date | 2021-09-01 |
Current Penalty | 4096.0 |
Initial Penalty | 4096.0 |
Final Order | 2021-11-23 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.300(b)(1): Power operated tool(s), designed to accommodate guards, were not equipped with such guards when in use: On or about: June 16, 2021 Location: 5726 Post rd. Bronx NY, 10471 a) Employee was using makita portable Angle grinder without safety guard. b) Employee was using Dewalt portable angle grinder without safety guard. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260451 A06 |
Issuance Date | 2021-09-01 |
Current Penalty | 4096.0 |
Initial Penalty | 4096.0 |
Final Order | 2021-11-23 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(a)(6): Scaffolds were not constructed in accordance with the design by a qualified person: On or about: June 16, 2021 Location: 5726 Post rd. Bronx NY, 10471 a) Employees were utilizing a scaffold that was not properly assembled exposing employees to fall hazards. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19260451 B01 |
Issuance Date | 2021-09-01 |
Current Penalty | 4096.0 |
Initial Penalty | 4096.0 |
Final Order | 2021-11-23 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) On or about: June 16, 2021 Location: 5726 Post rd. Bronx NY, 10471 a) Employees were working on scaffold that was not fully planked exposing employees to fall hazards. |
Citation ID | 01004 |
Citaton Type | Serious |
Standard Cited | 19260451 H01 |
Issuance Date | 2021-09-01 |
Current Penalty | 4096.0 |
Initial Penalty | 4096.0 |
Final Order | 2021-11-23 |
Nr Instances | 2 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(h)(1): Each employee on a scaffold was not provided with additional protection from falling hand tools, debris, and other small objects through the installation of toe boards, screens, guardrail systems, or through the erection of debris nets, catch platforms, or canopy structures that contain or deflect the falling objects: On or about: June 16, 2021 Location: 5726 Post rd. Bronx NY, 10471 a) Toe boards were not installed on scaffold to prevent tools or material from falling. Employees were exposed to struck by hazards. b) Scaffold piece hanging on the top of scaffold was not correctly installed exposing employees to struck by hazard. |
Citation ID | 01005 |
Citaton Type | Serious |
Standard Cited | 19261053 B16 |
Issuance Date | 2021-09-01 |
Current Penalty | 2341.0 |
Initial Penalty | 2341.0 |
Final Order | 2021-11-23 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Referral |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(16): Portable ladder(s) with structural defects, such as, but not limited to, broken or missing rungs, cleats, or steps, broken or split rails, corroded components, or other faulty or defective components: On or about: June 16, 2021 Location: 5726 Post rd. Bronx NY, 10471 a) Employees were using extension ladder that had bent rung and damaged cleat to access the second floor of the house exposing employees to a fall hazard. |