Search icon

TETRA STEEL CORP

Company Details

Name: TETRA STEEL CORP
Jurisdiction: New York
Legal type: FOREIGN BUSINESS CORPORATION
Status: Active
Date of registration: 17 May 2017 (8 years ago)
Entity Number: 5138252
ZIP code: 07731
County: Richmond
Place of Formation: New Jersey
Address: 133 NEWBURY ROAD, HOWELL, NJ, United States, 07731

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 133 NEWBURY ROAD, HOWELL, NJ, United States, 07731

Filings

Filing Number Date Filed Type Effective Date
170517000059 2017-05-17 APPLICATION OF AUTHORITY 2017-05-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342466687 0215000 2017-08-28 170 WEST 79TH STREET, NEW YORK, NY, 10024
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2017-08-28
Emphasis L: FALL
Case Closed 2018-06-21

Related Activity

Type Complaint
Activity Nr 1257522
Safety Yes
Type Inspection
Activity Nr 1258881
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2018-02-23
Abatement Due Date 2018-03-14
Current Penalty 2313.0
Initial Penalty 3696.0
Final Order 2018-03-22
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds shall be fully planked or decked between the front uprights and the guardrail supports. Location: 170 West 79th Street New York, NY On or about: August 28th, 2017 a) Worker drilling holes on a steel beam for safety netting was standing approximately 12 to 13 feet high, on the second tier of a two tier tubular welded frame scaffold that was not fully planked.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2018-02-23
Abatement Due Date 2018-03-14
Current Penalty 3774.0
Initial Penalty 5174.0
Final Order 2018-03-22
Nr Instances 1
Nr Exposed 1
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Location: 170 West 79th Street New York, NY On or about: August 28th, 2017 a) Employee used the cross braces of a two tier 12 to 13 foot high tubular welded frame scaffold to access the work platform.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261051 A
Issuance Date 2018-02-23
Current Penalty 1200.0
Initial Penalty 2217.0
Final Order 2018-03-22
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1051(a): Stairway(s) or ladder(s) were not provided at all personnel points of access where there was a break in elevation of 19 inches (48 cm) or more, or no ramp, runway, sloped embankment, or personnel hoist was provided: Location: 170 West 79th Street New York, NY On or about: August 28th, 2017 a) A break in elevation greater than 19 inches (approximately 22 Inches) on the roof where employees were working building a play deck for a school.
Citation ID 01004
Citaton Type Serious
Standard Cited 19261052 C01 I
Issuance Date 2018-02-23
Current Penalty 2313.0
Initial Penalty 3696.0
Final Order 2018-03-22
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: Location: 170 West 79th Street New York, NY On or about: August 28th, 2017 a) Employees used stairs that were not equipped with at least one handrail. Employees used the stairs to access the work area on the roof.

Date of last update: 07 Mar 2025