Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2023-06-01
|
Emphasis |
L: FALL, P: FALL
|
Case Closed |
2024-01-02
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2023-06-08 |
Abatement Due Date |
2023-06-14 |
Current Penalty |
3349.0 |
Initial Penalty |
3349.0 |
Final Order |
2023-07-12 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1):When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. a) On or about June 1, 2023, at 213 Stewart Ave, Garden City, NY 11530 Employees were observed climbing up and down the frames of a fabricated frame scaffold, that did not have an access ladder. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19 |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VII |
Issuance Date |
2023-06-08 |
Abatement Due Date |
2023-06-14 |
Current Penalty |
3349.0 |
Initial Penalty |
3349.0 |
Final Order |
2023-07-12 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. a) On or about June 1, 2023, at 213 Stewart Ave, Garden City, NY 11530 Employees were observed working on the third level of a fabricated frame scaffold, without a means of fall protection. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19 |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B13 |
Issuance Date |
2023-06-08 |
Abatement Due Date |
2023-06-14 |
Current Penalty |
3349.0 |
Initial Penalty |
3349.0 |
Final Order |
2023-07-12 |
Nr Instances |
1 |
Nr Exposed |
2 |
Related Event Code (REC) |
Imminent Danger |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b) a) On or about June 1, 2023, at 213 Stewart Ave, Garden City, NY 11530 Employees were observed walking on the pitched roof of a two story residence, without a means of fall protection. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19 |
|
|