Name: | JASON NAPLES CONSTRUCTION, LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 12 Jun 2017 (8 years ago) |
Entity Number: | 5152406 |
ZIP code: | 14207 |
County: | Erie |
Place of Formation: | New York |
Address: | 58 RANO STREET, BUFFALO, NY, United States, 14207 |
Name | Role | Address |
---|---|---|
JASON NAPLES | DOS Process Agent | 58 RANO STREET, BUFFALO, NY, United States, 14207 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
170921000227 | 2017-09-21 | CERTIFICATE OF PUBLICATION | 2017-09-21 |
170612010059 | 2017-06-12 | ARTICLES OF ORGANIZATION | 2017-06-12 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
344538467 | 0213600 | 2020-01-02 | 245 CHANDLER STREET, BUFFALO, NY, 14207 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260451 G01 I |
Issuance Date | 2020-01-10 |
Current Penalty | 1750.0 |
Initial Penalty | 2842.0 |
Final Order | 2023-01-09 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 1/2/20 at a roof project located at 245 Chandler Street, Buffalo, New York; employees performing roofing activities from a ladder jack scaffold approximately 18 feet high were not protected from falling by a personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B11 |
Issuance Date | 2020-01-10 |
Current Penalty | 1750.0 |
Initial Penalty | 2842.0 |
Final Order | 2023-01-09 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 1/2/20 at a roof project located at 245 Chandler Street, Buffalo, New York; employees were replacing the roof of a two story house. The roof had an 12 in 12 pitch and an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED |
Inspection Type | Unprog Other |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2019-11-19 |
Emphasis | L: FALL |
Case Closed | 2019-12-06 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260416 A01 |
Issuance Date | 2019-11-26 |
Current Penalty | 1449.0 |
Initial Penalty | 1932.0 |
Final Order | 2019-12-20 |
Nr Instances | 1 |
Nr Exposed | 5 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.416(a)(1): Employees were permitted to work in proximity to electric power circuits and were not protected against electric shock by de-energizing and grounding the circuits or effectively guarding the circuits by insulation or other means: a) On or about 11/19/19 at 1085 Niagara Street, Buffalo, NY; employees were exposed to contact with 480 volts AC when the ladder on the north side of the building was located approximately 24 inches away from the service lines coming into the building. NO ABATEMENT CERTIFICATION REQUIRED |
Date of last update: 07 Mar 2025