Search icon

CHEP SERVICES, LLC

Company Details

Name: CHEP SERVICES, LLC
Jurisdiction: New York
Legal type: FOREIGN LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 08 Aug 2017 (8 years ago)
Entity Number: 5182851
ZIP code: 10005
County: Onondaga
Place of Formation: Delaware
Address: 28 LIBERTY ST., NEW YORK, NY, United States, 10005

Agent

Name Role Address
C T CORPORATION SYSTEM Agent 28 LIBERTY ST., NEW YORK, NY, 10005

DOS Process Agent

Name Role Address
C T CORPORATION SYSTEM DOS Process Agent 28 LIBERTY ST., NEW YORK, NY, United States, 10005

History

Start date End date Type Value
2019-01-28 2023-08-01 Address 28 LIBERTY ST., NEW YORK, NY, 10005, USA (Type of address: Registered Agent)
2019-01-28 2023-08-01 Address 28 LIBERTY ST., NEW YORK, NY, 10005, USA (Type of address: Service of Process)
2017-08-08 2019-01-28 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Registered Agent)
2017-08-08 2019-01-28 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
230801005216 2023-08-01 BIENNIAL STATEMENT 2023-08-01
210901000197 2021-09-01 BIENNIAL STATEMENT 2021-09-01
190904060847 2019-09-04 BIENNIAL STATEMENT 2019-08-01
SR-79874 2019-01-28 CERTIFICATE OF CHANGE 2019-01-28
SR-79875 2019-01-28 CERTIFICATE OF CHANGE 2019-01-28
170808000253 2017-08-08 APPLICATION OF AUTHORITY 2017-08-08

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343863544 0215800 2019-03-20 6600 NEW VENTURE GEAR DRIVE, EAST SYRACUSE, NY, 13057
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-03-20
Emphasis N: DUSTEXPL, N: AMPUTATE, P: AMPUTATE
Case Closed 2019-07-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2019-04-09
Current Penalty 3220.0
Initial Penalty 4830.0
Final Order 2019-04-30
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.212(a)(1): Machine guarding was not provided to protect operator(s) and other employees from hazard(s) created by rotating parts: a) Maintenance Cage, on or about 3/20/19: Rotating chuck on a Ryobi drill press was not guarded.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19100242 A
Issuance Date 2019-04-09
Current Penalty 3220.0
Initial Penalty 4830.0
Final Order 2019-04-30
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.242(a): Hand and portable powered tools or equipment were not kept in safe condition: a) Sort Machine 600, on or about 3/20/19: Compressed air wand used for cleaning purposes had a missing dead man trigger switch.
Citation ID 01002B
Citaton Type Serious
Standard Cited 19100242 B
Issuance Date 2019-04-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-04-30
Nr Instances 2
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.242(b): Compressed air used for cleaning purposes was not reduced to less than 30 p.s.i.: a) Sort Machine 600, on or about 3/20/19: Compressed air wand used for cleaning purposes measured >100 psi. b) Repair Line, on or about 3/2/19: Compressed air wand used for cleaning purposes measured >100 psi.
Citation ID 02001
Citaton Type Other
Standard Cited 19100305 G01 IV A
Issuance Date 2019-04-09
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-04-30
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(g)(1)(iv)(A): Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) Maintenance Cage, on or about 3/20/19: A power strip providing current to a cutoff saw and a grinder was attached to a workbench and being used as permanent wiring.

Date of last update: 24 Mar 2025