Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-12-13
|
Emphasis |
L: FALL, P: FALL, L: LOCALTARG
|
Case Closed |
2021-03-18
|
Related Activity
Type |
Inspection |
Activity Nr |
1451591 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001A |
Citaton Type |
Serious |
Standard Cited |
19260501 B01 |
Issuance Date |
2020-04-21 |
Current Penalty |
0.0 |
Initial Penalty |
5398.0 |
Final Order |
2021-03-18 |
Nr Instances |
2 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems. a) At the jobsite, on the deck at the rear of the project building, on or about 12/13/19: Employees were working on a partially covered working surface exposed to a fall of 10 feet without fall protection of any kind. b) At the jobsite, on the second floor inside the project building, on or about 12/13/19: Employees were exposed to 10 foot fall hazards where guard rails-were removed from 2 stairwells. |
|
Citation ID |
01001B |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 I |
Issuance Date |
2020-04-21 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Final Order |
2021-03-18 |
Nr Instances |
3 |
Nr Exposed |
3 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(i): Each employee on walking/working surfaces was not protected from falling through holes (including skylights) more than 6 feet (1.8 m) above lower levels, by personal fall arrest systems, covers, or guardrail systems erected around the opening: a) At the jobsite, on the deck at the rear of the project building, on or about 12/13/19: Employees were working and transiting across the unfinished surface, where they were exposed to gaps in the decking. b) At the jobsite, on the second floor of the project building, on or about 12/13/19: Employees were transiting an area where the opening for a utility chase exposed workers to injury. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261052 C01 I |
Issuance Date |
2020-04-21 |
Current Penalty |
0.0 |
Initial Penalty |
2313.0 |
Final Order |
2021-03-18 |
Nr Instances |
4 |
Nr Exposed |
3 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(1)(i): Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) At the jobsite, in a stairwell between the first and second floors, on or about 12/13/19: Employees were not provided handrails to negotiate these stairs. b) At the jobsite, in a stairwell between the first and second floors, on or about 12/13/19: Employees were not provided handrails to negotiate these stairs. c) At the jobsite, in the stairwell between the first and basement level, on or about 12/13/19: Employees were not provided handrails to negotiate these stairs. d) At the jobsite, in the stairwell between the first and basement level, on or about 12/13/19: Employees were not provided handrails to negotiate these stairs. |
|
|