MIDLAKES INSULATION, INC.

Company Details

Name: MIDLAKES INSULATION, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Inactive
Date of registration: 19 Oct 2017 (7 years ago)
Date of dissolution: 20 Sep 2021
Entity Number: 5220858
ZIP code: 14456
County: Cayuga
Place of Formation: New York
Address: PO BOX 633, GENEVA, NY, United States, 14456

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
MIDLAKES INSULATION, INC. DOS Process Agent PO BOX 633, GENEVA, NY, United States, 14456

History

Start date End date Type Value
2017-10-19 2021-09-20 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2017-10-19 2022-04-14 Address PO BOX 633, GENEVA, NY, 14456, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
220414001680 2021-09-20 CERTIFICATE OF DISSOLUTION-CANCELLATION 2021-09-20
171019010469 2017-10-19 CERTIFICATE OF INCORPORATION 2017-10-19

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343790895 0215800 2019-02-19 1894 FLEMING SCIPIO TOWNLINE RD, UNION SPRINGS, NY, 13160
Inspection Type Complaint
Scope Complete
Safety/Health Health
Close Conference 2019-03-28
Case Closed 2019-08-26

Related Activity

Type Complaint
Activity Nr 1425302
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100134 C01
Issuance Date 2019-04-08
Abatement Due Date 2019-05-13
Current Penalty 2557.5
Initial Penalty 3410.0
Final Order 2019-04-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(c)(1): A written respiratory protection program that included the provisions in 29 CFR 1910.134(c)(1)(i) - (ix) with worksite specific procedures was not established and implemented for required respirator use: a) Through the facility and at jobsites, on or about 2/19/19: A respiratory protection program was not developed for employees using powered air purifying respirators and full face respirators while applying spray foam insulation containing chemicals including, but not limited to, methylene diphenyl diisocyanate (CAS # 101-68-8). Abatement certification must be submitted for this item.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100134 E01
Issuance Date 2019-04-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-04-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(e)(1): The employer did not provide a medical evaluation to determine the employee's ability to use a respirator, before the employee was fit tested or required to use the respirator in the workplace: a) Through the facility and at jobsites, on or about 2/19/19: Medical evaluations were not provided for employees using powered air purifying respirators and full face respirators while applying spray foam insulation containing chemicals including, but not limited to, methylene diphenyl diisocyanate (CAS # 101-68-8).
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100134 K03
Issuance Date 2019-04-08
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2019-04-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.134(k)(3): Training was not provided prior to requiring employees to use a respirator in the workplace: a) Through the facility and at jobsites, on or about 2/19/19: Training on respirators was not provided for employees using powered air purifying respirators and full face respirators while applying spray foam insulation containing chemicals including, but not limited to, methylene diphenyl diisocyanate (CAS # 101-68-8).
Citation ID 01002
Citaton Type Serious
Standard Cited 19100305 B01 II
Issuance Date 2019-04-08
Current Penalty 1704.75
Initial Penalty 2273.0
Final Order 2019-04-27
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.305(b)(1)(ii): Unused openings in boxes, cabinets, or fittings were not effectively closed: a) Electrical box in 2005 International truck, on or about 2/19/19: Openings in the circuit breaker box were not covered to prevent contact with live electrical parts.
Citation ID 01003
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2019-04-08
Current Penalty 1086.75
Initial Penalty 1449.0
Final Order 2019-04-27
Nr Instances 1
Nr Exposed 4
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.1200(h)(1): Employees were not provided effective information and training on hazardous chemicals in their work area at the time of their initial assignment and whenever a new hazard that the employees had not been previously trained about was introduced into their work area: a) Throughout the facility, on or about 2/19/19: Information and training was not provided on the hazards of chemicals in the workplace for employees applying spray foam insulation containing chemicals including, but not limited to, methylene diphenyl diisocyanate (CAS # 101-68-8). Abatement certification must be submitted for this item.

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
3062553 Intrastate Non-Hazmat 2017-10-26 - - 3 2 Private(Property)
Legal Name MIDLAKES INSULATION INC
DBA Name MIDLAKES SPRAYFOAM
Physical Address 1894 FLEMING SCIPIO TOWN LINE RD , UNION SPRINGS, NY, 13160, US
Mailing Address 4069 ROUTE 14 SOUTH , GENEVA, NY, 14456, US
Phone (315) 720-5573
Fax -
E-mail DREEDER@ROCHESTER.RR.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 0
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 0
Vehicle Maintenance BASIC Roadside Performance measure value 0
Total Number of Vehicle Inspections for the measurement period 0
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 0
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 0
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 0
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 0

Date of last update: 24 Mar 2025

Sources: New York Secretary of State