Search icon

V.C.M. ROOFING & SIDING CORP

Company Details

Name: V.C.M. ROOFING & SIDING CORP
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 23 Oct 2017 (8 years ago)
Entity Number: 5222071
ZIP code: 11901
County: Suffolk
Place of Formation: New York
Address: 59 VAIL AVE, FLANDERS, NY, United States, 11901

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 59 VAIL AVE, FLANDERS, NY, United States, 11901

Filings

Filing Number Date Filed Type Effective Date
171023010313 2017-10-23 CERTIFICATE OF INCORPORATION 2017-10-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343180105 0214700 2018-05-10 70 NARROW LANE, BRIDGEHAMPTON, NY, 11932
Inspection Type FollowUp
Scope NoInspection
Safety/Health Safety
Close Conference 2018-05-10
Emphasis L: FALL
Case Closed 2018-09-10

Related Activity

Type Inspection
Activity Nr 1278217
Safety Yes
342782174 0214700 2017-11-08 70 NARROW LANE, BRIDGEHAMPTON, NY, 11932
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2017-11-08
Emphasis L: FALL, P: FALL
Case Closed 2023-04-04

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2017-12-11
Current Penalty 2173.0
Initial Penalty 2173.0
Final Order 2018-01-11
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents: a) Worksite, 70 Narrow Lane, Bridgehampton, NY, roof of residence- Employees were using a pneumatic nail gun to install cedar shingle siding on a residence and were not wearing eye protection; on or about 11/8/2017. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2017-12-11
Abatement Due Date 2017-12-15
Current Penalty 2716.0
Initial Penalty 2716.0
Final Order 2018-01-11
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a) Worksite, 70 Narrow Lane, Bridgehampton, NY, roof of residence- Employees installing siding to a residence were working from a porch roof at a height approximately 10 feet. The employees were working without fall protection; on or about 11/8/17. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2017-12-11
Abatement Due Date 2017-12-15
Current Penalty 3803.0
Initial Penalty 3803.0
Final Order 2018-01-11
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladders were used for purposes other than the purposes for which they were designed: a) Worksite, 70 Narrow Lane, Bridgehampton, NY- Employees were installing shingles to the side of a residence and was not protected from falls by proper use of the ladder; on or about 11/8/17. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.

Date of last update: 24 Mar 2025