Inspection Type |
Unprog Rel
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-10-25
|
Case Closed |
2022-06-30
|
Related Activity
Type |
Inspection |
Activity Nr |
1440666 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260021 B02 |
Issuance Date |
2020-04-22 |
Abatement Due Date |
2020-05-04 |
Current Penalty |
6334.0 |
Initial Penalty |
9446.0 |
Final Order |
2020-05-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.21(b)(2): The employer did not instruct each employee in the recognition and avoidance of unsafe conditions and the regulations applicable to his work environment to control or eliminate any hazards or other exposure to illness or injury. a) Elevator running platform, elevator #1: The employer did not instruct each employee in the recognition and avoidance of unsafe conditions applicable to operating and working from an elevator running platform in an elevator shaft. On or about 10/24/19. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19261203 A |
Issuance Date |
2020-04-22 |
Abatement Due Date |
2020-05-04 |
Current Penalty |
6332.0 |
Initial Penalty |
9446.0 |
Final Order |
2020-05-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1203(a): Before it began work at a worksite, the employer did not ensure that a competent person identified all confined spaces in which one or more of the employees it directed have worked, and/or did not identify each space that was a permit space, through consideration and evaluation of the elements of that space, including testing as necessary. a) Elevator running platform, elevator #1: Employees worked from a temporary elevator platform applied fireproofing materials to the walls of the shaft. Employees moved up and down the shaft. The employer had not evaluated the workspace to identify if a confined space or a permit required confined space existed. On or about 10/24/19. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19261207 A |
Issuance Date |
2020-04-22 |
Abatement Due Date |
2020-05-04 |
Current Penalty |
6334.0 |
Initial Penalty |
9446.0 |
Final Order |
2020-05-29 |
Nr Instances |
1 |
Nr Exposed |
3 |
Related Event Code (REC) |
Accident |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1207(a): The employer did not provide training to each employee whose work is regulated by this standard, at no cost to the employee, and did not ensure that the employee possessed the understanding, knowledge, and skills necessary for the safe performance of duties assigned under this standard. a) Elevator running platform, elevator #1: Employees worked from a temporary elevator platform applied fireproofing materials to the walls of the shaft. Employees moved up and down the shaft. The employer did not provide training to each employee to ensure that the employee possessed the understanding, knowledge, and skills necessary for the safe performance of duties in a confined space or a permit required confined space. On or about 10/24/19. |
|
|