Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Emphasis |
L: FALL
|
Related Activity
Type |
Referral |
Activity Nr |
1768217 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1532528 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1531058 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260050 G |
Issuance Date |
2021-05-27 |
Abatement Due Date |
2021-06-07 |
Current Penalty |
4096.0 |
Initial Penalty |
4096.0 |
Contest Date |
2021-06-17 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
1 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.50(g): Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: Location: 233 East Main St. Elmsford NY 10523 a) On or about May 17, 2021, employees were working with hazardous chemicals such as Portland Cement and the employer did not provide a suitable facility for quick drenching or flushing of the eyes within the work area for immediate emergency use. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260095 A |
Issuance Date |
2021-05-27 |
Abatement Due Date |
2021-06-07 |
Current Penalty |
5461.0 |
Initial Penalty |
5461.0 |
Contest Date |
2021-06-17 |
Nr Instances |
1 |
Nr Exposed |
15 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.95(a): Personal protective equipment, including personal protective equipment for eyes, face, head, and extremities, protective clothing, respiratory devices, and protective shields and barriers, was not provided, used, or maintained in a sanitary and reliable condition it was necessary by reason of hazards of processes or environment, chemical hazards, radiological hazards, or mechanical irritants encountered in a manner capable of causing injury or impairment in the function of any part of the body through absorption, inhalation, or physical contact: Location: 233 East Main St. Elmsford NY 105231 a) On or about May 17, 2021, the employer did not require the use of appropriate personal protective equipment, to include but not limited to gloves and eye protection, when employees were working with hazardous chemicals such as Portland Cement. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260451 G01 VI |
Issuance Date |
2021-05-27 |
Current Penalty |
9557.0 |
Initial Penalty |
9557.0 |
Contest Date |
2021-06-17 |
Nr Instances |
2 |
Nr Exposed |
15 |
Gravity |
10 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(g)(1)(vi): Each employee performing overhand bricklaying operations from a supported scaffold was not protected from falling from all open sides and ends of the scaffold by the use of a personal fall arrest system or guardrail system (with minimum 200 pound toprail capacity): Location: 233 East Main St. Elmsford NY 10523 a) On or about May 17th, 2021, employees were exposed to an approximate 25ft fall hazard while working on a scaffold that did not have adequate fall protection on the ends - located at the North East side of the building. b) On or about May 17th, 2021, employees were exposed to an approximate 33ft fall hazard while working on a scaffold that did not have adequate fall protection on the sides or ends - located at the South West side of the building. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260701 B |
Issuance Date |
2021-05-27 |
Current Penalty |
6827.0 |
Initial Penalty |
6827.0 |
Contest Date |
2021-06-17 |
Nr Instances |
1 |
Nr Exposed |
8 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.701(b): All protruding reinforcing steel, onto and/or into which employees could fall, was not guarded to eliminate the hazard of impalement: Location: 233 East Main St. Elmsford NY 10523 a) On or about May 17th, 2021, employees were exposed to impalement hazards due to all protruding reinforcing steel not being guarded while working on a scaffold that did not have adequate fall protection on the sides or ends - located at the South West side of the building. |
|
|