Search icon

SECURE ROOFING INC.

Company Details

Name: SECURE ROOFING INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 22 Nov 2017 (7 years ago)
Entity Number: 5239795
ZIP code: 10950
County: Orange
Place of Formation: New York
Address: 18 ZENTA RD. UNIT 201, MONROE, NY, United States, 10950
Principal Address: 173 woodpoint road, Brooklyn, NY, United States, 11211

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 18 ZENTA RD. UNIT 201, MONROE, NY, United States, 10950

Chief Executive Officer

Name Role Address
MENACHEM Y BANDA Chief Executive Officer 1214 46TH STREET, 3RD FLOOR, BROOKLYN, NY, United States, 11219

History

Start date End date Type Value
2025-01-02 2025-02-20 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-12-13 2025-01-02 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-12-07 2024-12-13 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-09-17 2024-12-07 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-09-12 2024-09-17 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-09-09 2024-09-12 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-08-12 2024-09-09 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-08-02 2024-08-12 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-07-26 2024-08-02 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-07-16 2024-07-26 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
220215004243 2022-02-14 CERTIFICATE OF AMENDMENT 2022-02-14
220208002335 2022-02-08 BIENNIAL STATEMENT 2022-02-08
180314000229 2018-03-14 CERTIFICATE OF CHANGE 2018-03-14
180307000450 2018-03-07 CERTIFICATE OF CHANGE 2018-03-07
171122010447 2017-11-22 CERTIFICATE OF INCORPORATION 2017-11-22

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344662333 0215000 2020-02-27 535 GRAND STREET, BROOKLYN, NY, 11211
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2020-02-27
Emphasis L: FALL
Case Closed 2021-05-03

Related Activity

Type Inspection
Activity Nr 1466228
Safety Yes
Type Referral
Activity Nr 1548308
Safety Yes
Type Inspection
Activity Nr 1468808
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C01 II
Issuance Date 2020-08-26
Current Penalty 0.0
Initial Penalty 10390.0
Contest Date 2020-09-22
Final Order 2021-05-03
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(1)(ii): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by installing guys, ties, and braces according to the manufacturer. Site: 535 Grand Street in Brooklyn, NY. On or about 02/26/2020. a) Employees were working on scaffolding that had tiebacks removed from the top and lower sections of the tubular welded frame scaffold erected on the beams at the side of the building.
344202460 0215000 2019-08-01 185 VERONICA PLACE, BROOKLYN, NY, 11226
Inspection Type Referral
Scope Complete
Safety/Health Safety
Close Conference 2019-08-01
Emphasis L: FALL

Related Activity

Type Referral
Activity Nr 1539151
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 C02 II
Issuance Date 2020-01-31
Current Penalty 3362.5
Initial Penalty 6748.0
Contest Date 2020-02-26
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(2)(ii): Unstable objects were used to support scaffolds or platform units: a) The Pump Jack scaffold pole was placed on top of a 10 inch high stack of wood to add height. Four employees on the scaffold at 25 ft elevation were exposed to scaffold collapse/ unstable scaffold hazard. Location: 185 Veronica Place, Brooklyn NY On or about 8/1/2019 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2020-01-31
Current Penalty 3362.5
Initial Penalty 6747.0
Contest Date 2020-02-26
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3): Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffolds structural integrity: a) The employer did not have a competent person inspect and ensure the 40 ft tall pump jack scaffold is safe for use; the scaffold was unstable due to insufficient bracing. Four employees on the scaffold at 25 ft elevation were exposed to scaffold collapse/ unstable scaffold hazard. Location: 185 Veronica Place, Brooklyn NY On or about 8/1/2019 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260452 J02
Issuance Date 2020-01-31
Current Penalty 3362.5
Initial Penalty 6747.0
Contest Date 2020-02-26
Final Order 2020-06-15
Nr Instances 4
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(2): Pump Jack scaffold poles were not secured to the structure by rigid triangular bracing or equivalent at the bottom, top, and other points as necessary. When the pump jack has to pass bracing already installed, an additional brace shall be installed approximately 4 feet (1.2 m) above the brace to be passed, and shall be left in place until the pump jack has been moved and the original brace reinstalled: a) The 40 ft tall pump jack scaffold poles only were braced at the top of the 40 ft tall poles; scaffold was swaying excessively. Four employees on the scaffold at 25 ft elevation were exposed to scaffold collapse/ unstable scaffold hazard. Location: 185 Veronica Place, Brooklyn NY On or about 8/1/2019 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01004A
Citaton Type Serious
Standard Cited 19260452 J03
Issuance Date 2020-01-31
Current Penalty 0.0
Initial Penalty 6747.0
Contest Date 2020-02-26
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(j)(3): When guardrails are used for fall protection, a workbench was used as the toprail which did not meet all the (guardrail) requirements in paragraphs (g)(4)(ii), (vii), (viii), and (xiii) of 1926.451: a) The pump jack scaffold had an incomplete guardrail/ workbench; there was a 10 ft long gap where there was no guardrail or workbench. Four employees on the scaffold at 25 ft elevation were exposed to unsafe scaffold/ fall hazard. Location: 185 Veronica Place, Brooklyn NY On or about 8/1/2019 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260454 C
Issuance Date 2020-01-31
Current Penalty 3362.5
Initial Penalty 6747.0
Contest Date 2020-02-26
Final Order 2020-06-15
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(c): Retraining was not provided when the employer has reason to believe the employee lacks the skill or understanding needed for safe work involving the erection, use or dismantling of scaffolds: a) Employer did not ensure employees who erect and use pump jack scaffolds are trained to ensure the scaffold will remain braced and stable when employer is installing vinyl siding; four employees on the scaffold at 25 ft elevation were exposed to unsafe scaffold, scaffold collapse hazard. Location: 185 Veronica Place, Brooklyn NY On or about 8/1/2019 NOTE: BECAUSE ABATEMENT OF THIS VIOLATION IS ALREADY DOCUMENTED IN THE CASEFILE, THE EMPLOYER NEED NOT SUBMIT CERTIFICATION NOR DOCUMENTATION OF ABATEMENT OF THIS VIOLATION AS NORMALLY REQUIRED BY 29 CFR 1903.19.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
3648068309 2021-01-22 0202 PPS 173 Woodpoint Rd, Brooklyn, NY, 11211-1512
Loan Status Date 2022-03-18
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 131985
Loan Approval Amount (current) 131985
Undisbursed Amount 0
Franchise Name -
Lender Location ID 456756
Servicing Lender Name Cross River Bank
Servicing Lender Address 885 Teaneck Rd, TEANECK, NJ, 07666-4546
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address Brooklyn, KINGS, NY, 11211-1512
Project Congressional District NY-07
Number of Employees 17
NAICS code 238160
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 456756
Originating Lender Name Cross River Bank
Originating Lender Address TEANECK, NJ
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 133315.7
Forgiveness Paid Date 2022-02-14

Date of last update: 24 Mar 2025

Sources: New York Secretary of State