Search icon

6600 MAIN STREET LLC

Company Details

Name: 6600 MAIN STREET LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 21 Dec 2017 (7 years ago)
Entity Number: 5254492
ZIP code: 14221
County: Erie
Place of Formation: New York
Address: 6600 Main Street, Williamsville, NY, United States, 14221

DOS Process Agent

Name Role Address
BUFFALO DENTAL GROUP, LLP DOS Process Agent 6600 Main Street, Williamsville, NY, United States, 14221

History

Start date End date Type Value
2023-11-13 2024-12-18 Address 6600 Main Street, Williamsville, NY, 14221, USA (Type of address: Service of Process)
2017-12-21 2023-11-13 Address 4845 MAIN STREET, WILLIAMSVILLE, NY, 14221, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
241218003658 2024-12-18 BIENNIAL STATEMENT 2024-12-18
231113003696 2023-11-13 BIENNIAL STATEMENT 2021-12-01
180625001004 2018-06-25 CERTIFICATE OF PUBLICATION 2018-06-25
171221010295 2017-12-21 ARTICLES OF ORGANIZATION 2017-12-21

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345618847 0213600 2021-11-01 6600 MAIN STREET, WILLIAMSVILLE, NY, 14221
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-11-01
Emphasis L: FALL, P: FALL
Case Closed 2022-03-08

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B14
Issuance Date 2022-01-10
Current Penalty 1989.0
Initial Penalty 1989.0
Final Order 2022-02-15
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(14):Each employee working on, at, above, or near wall openings (including those with chutes attached), where the outside bottom edge of the wall opening was 6 feet (1.8 m) or more above lower levels and the inside bottom edge of the wall opening is less than 39 inches (1.0 M) above the walking/working surface, is not protected from falling by the use of a guardrail system, a safety net system, or a personal fall arrest system: a) On or about 11/1/2021, at the first floor area of the site, Williamsville, NY. The wall opening, located at the opposite side of stairways to the basement, was not protected from employees' falling by the use of a guardrail system, a safety net system, or a personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19261052 C01 I
Issuance Date 2022-01-10
Current Penalty 1989.0
Initial Penalty 1989.0
Final Order 2022-02-15
Nr Instances 1
Nr Exposed 3
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(1)(i):Stairways having four or more risers or rising more than 30 inches (76 cm), whichever is less, were not equipped with at least one handrail: a) On or about 11/1/2021, at the first floor area of the site, Williamsville, NY. The stairways, with 15 riser steps to mid landing, were not equipped with at least one handrail. NO ABATEMENT CERTIFICATION REQUIRED

Date of last update: 24 Mar 2025