Search icon

D.V.F. CONSTRUCTION, CORP.

Company Details

Name: D.V.F. CONSTRUCTION, CORP.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 23 Feb 2018 (7 years ago)
Entity Number: 5292199
ZIP code: 10458
County: Bronx
Place of Formation: New York
Address: 2343 ARTHUR AVENUE, BRONX, NY, United States, 10458

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
D.V.F. CONSTRUCTION, CORP DOS Process Agent 2343 ARTHUR AVENUE, BRONX, NY, United States, 10458

Chief Executive Officer

Name Role Address
CITLALLI CABRERA Chief Executive Officer 2343 ARTHUR AVENUE, SUITE BB1, BRONX, NY, United States, 10458

History

Start date End date Type Value
2024-11-22 2025-01-22 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2023-06-13 2024-11-22 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2018-02-23 2023-06-13 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
220721003303 2022-07-21 BIENNIAL STATEMENT 2022-02-01
180223010133 2018-02-23 CERTIFICATE OF INCORPORATION 2018-02-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346744147 0215000 2023-06-02 213 14TH STREET, BROOKLYN, NY, 11215
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-06-02
Emphasis L: LOCALTARG, P: LOCALTARG
Case Closed 2023-11-29

Related Activity

Type Inspection
Activity Nr 1674407
Health Yes
Type Inspection
Activity Nr 1674402
Safety Yes
Type Inspection
Activity Nr 1674416
Health Yes
346744162 0215000 2023-06-02 213 14TH STREET, BROOKLYN, NY, 11215
Inspection Type Prog Related
Scope Partial
Safety/Health Health
Close Conference 2023-06-02
Emphasis N: HEATNEP, P: HEATNEP
Case Closed 2023-11-29

Related Activity

Type Inspection
Activity Nr 1674414
Safety Yes
344574132 0215000 2020-01-23 118 W. 139TH ST, NEW YORK, NY, 10030
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2020-01-23
Emphasis L: LOCALTARG, P: LOCALTARG

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2020-02-27
Current Penalty 3856.0
Initial Penalty 3856.0
Final Order 2020-03-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites. a) 3rd Fl. bedroom: On or about January 23, 2020 An employee used a Skilsaw Circular saw was supplied power by an extension cord and it was not protected by an GFCI or assured grounding program.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 F06
Issuance Date 2020-02-27
Current Penalty 3856.0
Initial Penalty 3856.0
Final Order 2020-03-27
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(f)(6): The path to ground from circuits, equipment, or enclosures was not permanent and continuous: a) 3rd Fl. bedroom: On or about January 23, 2020 An employee used a portable light which was plugged into the wall outlet but was missing the ground pin.
344565684 0215000 2020-01-16 118 WEST 139TH STREET, NEW YORK, NY, 10030
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2020-01-16
Emphasis L: LOCALTARG, P: LOCALTARG
Case Closed 2024-07-16

Related Activity

Type Inspection
Activity Nr 1456524
Safety Yes
Type Inspection
Activity Nr 1456496
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260403 I02 I
Issuance Date 2020-06-19
Current Penalty 3470.0
Initial Penalty 3470.0
Final Order 2020-07-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures. Site: 118 West 139th Street in New York, NY. 5th floor of site. On or about 1/16/2020, a) An employee working on the 5th floor was exposed to live electrical parts that were not guarded against accidental contact.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B01
Issuance Date 2020-06-19
Current Penalty 3470.0
Initial Penalty 3470.0
Final Order 2020-07-17
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(1): Each employee on a working/walking surface (horizontal and vertical surface) with an unprotected side or edge which was 6 feet ( 1.8m ) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: Site: 118 West 139th Street in New York, NY. 3rd floor of site. On or about 1/16/2020, a) An employee working on a wooden beam installing metal bracing on the 3rd floor with an unprotected edge was exposed to a fall hazard without being protected.