Search icon

NORTH CLYMER CONSTRUCTION LLC

Company Details

Name: NORTH CLYMER CONSTRUCTION LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 15 Mar 2018 (7 years ago)
Entity Number: 5304555
ZIP code: 14767
County: Chautauqua
Place of Formation: New York
Address: 7559 CLYMER CENTER RD, PANAMA, NY, United States, 14767

DOS Process Agent

Name Role Address
ANDREW MILLER DOS Process Agent 7559 CLYMER CENTER RD, PANAMA, NY, United States, 14767

Agent

Name Role Address
AMANDA MILLER Agent 7723 ROUTE 474, PANAMA, NY, 14767

History

Start date End date Type Value
2018-03-15 2024-07-30 Address 7723 ROUTE 474, PANAMA, NY, 14767, USA (Type of address: Registered Agent)
2018-03-15 2024-07-30 Address 7723 ROUTE 474, PANAMA, NY, 14767, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
240730019179 2024-07-30 BIENNIAL STATEMENT 2024-07-30
230118002872 2023-01-18 BIENNIAL STATEMENT 2022-03-01
180315010214 2018-03-15 ARTICLES OF ORGANIZATION 2018-03-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347947673 0213600 2024-12-20 11168 STAGE RD, CLARENCE CENTER, NY, 14032
Inspection Type Unprog Other
Scope Partial
Safety/Health Safety
Close Conference 2024-12-20
Emphasis N: FALL
347312233 0213600 2024-02-26 136 - 138 GRANT BOULEVARD, WEST SENECA, NY, 14218
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2024-02-26
Emphasis N: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1731227
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Willful
Standard Cited 19260501 B11
Issuance Date 2024-06-26
Current Penalty 27655.0
Initial Penalty 27655.0
Final Order 2024-07-23
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 2/26/2024 at a roof project located at Grant Boulevard. Lot 48B/A, Lackawanna, New York; employees were shingling a new roof of a two story house. The roof had a 5 in 12 pitch and an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Willful
Standard Cited 19261053 B01
Issuance Date 2024-06-26
Current Penalty 27655.0
Initial Penalty 27655.0
Final Order 2024-07-23
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about 2/26/2024 at a roof project located at Grant Boulevard, Lot 48B/A, Lackawanna, New York; employees were placing shingles on the roof of a new house. Employees were using extension ladders to access the work area on the roof. The ladders extended 1 foot above the landing surface. NO ABATEMENT CERTIFICATION REQUIRED
346849565 0213600 2023-07-19 SOUTH DRIVE LOT 18 B/A, LACKAWANNA, NY, 14218
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-07-19
Emphasis L: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1684962
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Willful
Standard Cited 19260501 B11
Issuance Date 2023-09-21
Current Penalty 26786.0
Initial Penalty 26786.0
Final Order 2023-10-19
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 7/16/2023 at a roof project located at South Drive. Lot 18B/A, Lackawanna, New York; employees were shingling a new roof of a two story house. The roof had an 5 in 12 pitch and an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001
Citaton Type Repeat
Standard Cited 19261053 B01
Issuance Date 2023-09-21
Current Penalty 6697.0
Initial Penalty 6697.0
Final Order 2023-10-19
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about 7/16/2023 at a roof project located at South Drive. Lot 18B/A, Lackawanna, New York; employees were placing shingles on the roof of a new house. Employees were using an extension ladder to access the work area on the roof. The ladder extended 1 foot above the landing surface. NO ABATEMENT CERTIFICATION REQUIRED North Clymer Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1623068, citation number 1, item number 2 and was affirmed as a final order on 10/17/22, with respect to a workplace located at 135 & 137 South Drive, Lackawanna, New York.
346783368 0213600 2023-06-16 4926 BRAUER ROAD, LOCKPORT, NY, 14094
Inspection Type Planned
Scope Partial
Safety/Health Health
Close Conference 2023-06-16
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Repeat
Standard Cited 19260501 B11
Issuance Date 2023-09-20
Current Penalty 8930.0
Initial Penalty 8930.0
Final Order 2023-10-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) 4934 Brauer Road, Pendleton, NY - On or about 6/16/2023, employees engaged in roofing work were exposed to falls of approximately 28'-30' while working at the edge and peak of the roof. The roof had an 5 in 12 pitch and an eave height of approximately 30 feet. There was no fall protection in use. North Clymer Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1623068, citation number 1, item number 1 and was affirmed as a final order on 10/17/22, with respect to a workplace located at 135 & 137 South Drive, Lackawanna, New York. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Repeat
Standard Cited 19261053 B01
Issuance Date 2023-09-20
Current Penalty 8930.0
Initial Penalty 8930.0
Final Order 2023-10-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) 4934 Brauer Road, Pendleton, NY - On or about 6/16/2023, the portable ladder used to access the roof extended less than 1 foot above the upper landing surface. Employees were using an extension ladder to access the work area on the roof. North Clymer Construction, LLC was previously cited for a violation of this occupational safety and health standard or its equivalent standard, which was contained in OSHA inspection number 1623068, citation number 1, item number 2 and was affirmed as a final order on 10/17/22, with respect to a workplace located at 135 & 137 South Drive, Lackawanna, New York. NO ABATEMENT CERTIFICATION REQUIRED
346230683 0213600 2022-06-24 135 & 137 SOUTH DRIVE, LACKAWANNA, NY, 14218
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2022-06-24
Emphasis L: FALL, P: FALL

Related Activity

Type Inspection
Activity Nr 1605540
Safety Yes
Type Inspection
Activity Nr 1605518
Safety Yes
Type Inspection
Activity Nr 1605520
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2022-09-20
Current Penalty 4144.0
Initial Penalty 4144.0
Final Order 2022-10-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 6/24/2022 at a roof project located at 135 & 137 South Drive, Lackawanna, New York; employees were placing shingles on the roof of two houses. The roof had an 5 in 12 pitch and an eave height of approximately 18 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2022-09-20
Current Penalty 4144.0
Initial Penalty 4144.0
Final Order 2022-10-17
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about 6/24/2022 at a roof project located at 135 & 137 South Drive, Lackawanna, New York; employees were placing shingles on the roof of two houses. Employees were using an extension ladder to access the work area on the roof. The ladder extended 1 foot above the landing surface. NO ABATEMENT CERTIFICATION REQUIRED
345714372 0213600 2022-01-05 5674 GLEN BROOK COURT, CLARENCE, NY, 14031
Inspection Type Prog Other
Scope Partial
Safety/Health Safety
Close Conference 2022-01-05
Emphasis L: FALL, P: FALL
Case Closed 2025-02-03

Related Activity

Type Inspection
Activity Nr 1571403
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 5A0001
Issuance Date 2022-01-13
Current Penalty 2926.0
Initial Penalty 2926.0
Final Order 2022-02-08
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line OSH ACT of 1970 Section (5)(a)(1): The employer did not furnish employment and a place of employment which were free from recognized hazards that were causing or likely to cause death or serious physical harm to employees in that employees were exposed to fall hazards: a) On or about 1/5/2022 at a residential construction site located at 5674 Glen Brook Court, Clarence, New York; employees were roofing an addition to a house from a job built work platform (pallet) attached to the forks of a rough terrain forklift. The use of a personnel platform was not approved for use by the forklift manufacturer, exposing employees to a fall hazards. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2022-01-13
Current Penalty 2926.0
Initial Penalty 2926.0
Final Order 2022-02-08
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 1/5/22 at a roof project located at 5674 Glen Brook Court, Clarence, New York; employees were placing shingles on the roof of a two story addition. The roof had a 7 in 12 pitch and an eave height of approximately 20 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED

Motor Carrier Census

USDOT Number Carrier Operation MCS-150 Form Date MCS-150 Mileage MCS-150 Year Power Units Drivers Operation Classification
3741607 Interstate 2024-10-22 90097 2024 1 1 Priv. Pass. (Business)
Legal Name NORTH CLYMER CONSTRUCTION LLC
DBA Name -
Physical Address 7559 CLYMER CENTER RD, PANAMA, NY, 14767-9632, US
Mailing Address 7559 CLYMER CENTER RD, PANAMA, NY, 14767-9632, US
Phone (716) 450-0727
Fax -
E-mail NORTHCLYMERCONST@YAHOO.COM

Safety Measurement System - All Transportation

Total Number of Inspections for the measurement period (24 months) 1
Driver Fitness BASIC Serious Violation Indicator No
Vehicle Maintenance BASIC Acute/Critical Indicator No
Unsafe Driving BASIC Acute/Critical Indicator No
Driver Fitness BASIC Roadside Performance measure value 0
Hours-of-Service (HOS) Compliance BASIC Roadside Performance measure value 0
Total Number of Driver Inspections for the measurment period 1
Vehicle Maintenance BASIC Roadside Performance measure value 30
Total Number of Vehicle Inspections for the measurement period 1
Controlled Substances and Alcohol BASIC Roadside Performance measure value 0
Unsafe Driving BASIC Roadside Performance Measure Value 1.55
Number of inspections with at least one Driver Fitness BASIC violation 0
Number of inspections with at least one Hours-of-Service BASIC violation 0
Total Number of Driver Inspections containing at least one Driver Out-of-Service Violation 0
Number of inspections with at least one Vehicle Maintenance BASIC violation 1
Total Number of Vehicle Inspections containing at least one Vehicle Out-of-Service violation 1
Number of inspections with at least one Controlled Substances and Alcohol BASIC violation 0
Number of inspections with at least one Unsafe Driving BASIC violation 1

Inspections

Unique report number of the inspection SPA0360175
State abbreviation that indicates the state the inspector is from NY
The date of the inspection 2024-01-26
ID that indicates the level of inspection Walk-around
State abbreviation that indicates where the inspection occurred NY
Time weight of the inspection 2
Number of Out-Of-Service violations related to Driver 0
Number of Out-Of-Service violations related to vehicle 5
Number of violations related to Hazardous Materials 0
Total number of Out-Of-Service violations 5
Total number of Out-Of-Service violations related to Hazardous Materials 0
Description of the type of the main unit STRAIGHT TRUCK
Description of the make of the main unit CHEV
License plate of the main unit 36469NC
License state of the main unit NY
Vehicle Identification Number of the main unit 1GAZGPFG6K1171289
Description of the type of the secondary unit SEMI-TRAILER
Description of the make of the secondary unit SURT
License plate of the secondary unit BT87027
License state of the secondary unit NY
Vehicle Identification Number of the secondary unit 56VBE1629KM653489
Unsafe Driving BASIC inspection Y
Hours-of-Service Compliance BASIC inspection Y
Driver Fitness BASIC inspection Y
Controlled Substances/Alcohol BASIC inspection Y
Vehicle Maintenance BASIC inspection Y
Total number of BASIC violations 10
Number of Unsafe Driving BASIC violations 1
Number of Hours-of-Service Compliance BASIC violations 0
Number of Driver Fitness BASIC violations 0
Number of Controlled Substances/Alcohol BASIC violations 0
Number of Vehicle Maintenance BASIC violations 9
Number of Hazardous Materials Compliance BASIC violations 0

Violations

The date of the inspection 2024-01-26
Code of the violation 39617C
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 4
The time weight that is assigned to a violation 2
The description of a violation Operating a CMV without proof of a periodic inspection
The description of the violation group Inspection Reports
The unit a violation is cited against Vehicle secondary unit
The date of the inspection 2024-01-26
Code of the violation 39395F
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 2
The time weight that is assigned to a violation 2
The description of a violation Emergency Equipment - Stopped vehicle warning devices missing or improper
The description of the violation group Emergency Equipment
The unit a violation is cited against Vehicle main unit
The date of the inspection 2024-01-26
Code of the violation 3939
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 2
The time weight that is assigned to a violation 2
The description of a violation Inoperable Required Lamp
The description of the violation group Clearance Identification Lamps/Other
The unit a violation is cited against Vehicle main unit
The date of the inspection 2024-01-26
Code of the violation 39387A
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation Y
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 2
The severity weight that is assigned to a violation 1
The time weight that is assigned to a violation 2
The description of a violation Warning flag required on projecting load
The description of the violation group Warning Flags
The unit a violation is cited against Vehicle secondary unit
The date of the inspection 2024-01-26
Code of the violation 39375A3
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation Y
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 2
The severity weight that is assigned to a violation 8
The time weight that is assigned to a violation 2
The description of a violation Tire-flat and/or audible air leak
The description of the violation group Tires
The unit a violation is cited against Vehicle secondary unit
The date of the inspection 2024-01-26
Code of the violation 39370D
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation Y
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 2
The severity weight that is assigned to a violation 3
The time weight that is assigned to a violation 2
The description of a violation No or improper safety chains or cables for full trailer
The description of the violation group Coupling Devices
The unit a violation is cited against Vehicle secondary unit
The date of the inspection 2024-01-26
Code of the violation 393102A
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 3
The time weight that is assigned to a violation 2
The description of a violation Improper securement system (tiedown assemblies)
The description of the violation group Tiedown
The unit a violation is cited against Vehicle secondary unit
The date of the inspection 2024-01-26
Code of the violation 393100A
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation Y
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 2
The severity weight that is assigned to a violation 1
The time weight that is assigned to a violation 2
The description of a violation No or improper load securement
The description of the violation group General Securement
The unit a violation is cited against Vehicle secondary unit
The date of the inspection 2024-01-26
Code of the violation 3927A
Name of the BASIC Vehicle Maintenance
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 4
The time weight that is assigned to a violation 2
The description of a violation Driver failing to conduct pre-trip inspection
The description of the violation group Inspection Reports
The unit a violation is cited against Driver
The date of the inspection 2024-01-26
Code of the violation 39216B
Name of the BASIC Unsafe Driving
The violation is identified as Out-Of-Service violation N
The weight that is assigned to a violation if it's identified as an Out-Of-Service violation 0
The severity weight that is assigned to a violation 7
The time weight that is assigned to a violation 2
The description of a violation Operating a property-carrying commercial motor vehicle while all other occupants are not properly restrained
The description of the violation group Seat Belt
The unit a violation is cited against Driver

Date of last update: 24 Mar 2025