Search icon

AMTECH YARNS, INC.

Company Details

Name: AMTECH YARNS, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 02 Apr 2018 (7 years ago)
Entity Number: 5315186
ZIP code: 13662
County: St. Lawrence
Place of Formation: New York
Address: 21 TRADE RD, MASSENA, NY, United States, 13662

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
AMTECH, INC. DOS Process Agent 21 TRADE RD, MASSENA, NY, United States, 13662

Filings

Filing Number Date Filed Type Effective Date
180402010135 2018-04-02 CERTIFICATE OF INCORPORATION 2018-04-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
346418171 0215800 2023-01-04 21 TRADE DRIVE, MASSENA, NY, 13662
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2023-01-04
Emphasis N: AMPUTATE

Related Activity

Type Complaint
Activity Nr 1979994
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100028 B03 I
Issuance Date 2023-03-28
Abatement Due Date 2024-02-15
Current Penalty 1500.0
Initial Penalty 3572.0
Contest Date 2023-04-12
Final Order 2024-01-29
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.28(b)(3)(i): The employer did not ensure each employee is protected from falling through any hole (including skylights) that is 4 feet (1.2 m) or more above a lower level by one or more of the following: covers, guardrail systems, travel restraint systems, or personal fall arrest systems, as required by sub-items A through D of this section. a) The Chimney, AmTech Yarns, Inc, 21 Trade Drive Massena, NY 13662, on or about 1/4/23: Employees were not protected from falling into the Chimney on the second floor of the process. A top rail is provided, but no mid-rail is provided for the fall hazard. Abatement certification is required.
Citation ID 01001B
Citaton Type Other
Standard Cited 19100146 C07 III
Issuance Date 2023-03-28
Abatement Due Date 2024-02-15
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2023-04-12
Final Order 2024-01-30
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 1910.146(c)(7)(iii) The employer shall document the basis for determining that all hazards in a permit space have been eliminated, through a certification that contains the date, the location of the space, and the signature of the person making the determination. The certification shall be made available to each employee entering the space or to that employee's authorized representative. 29 CFR 1910.146(c)(1): The employer did not evaluate the workplace to determine if any spaces were permit-required confined spaces: a) The Chimney, AmTech Yarns, Inc, 21 Trade Drive Massena, NY 13662, on or about 1/4/23, The employer did not evaluate the chimney to determine if it was a permit required confined spaced. Employees are required to break the plane of the chimney to conduct cleaning and to perform die wipes. Abatement certification is required.
Citation ID 01002
Citaton Type Serious
Standard Cited 19100095 C01
Issuance Date 2023-03-28
Abatement Due Date 2024-02-15
Current Penalty 3500.0
Initial Penalty 5358.0
Contest Date 2023-04-12
Final Order 2024-01-29
Nr Instances 2
Nr Exposed 12
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.95(c)(1): A continuing, effective hearing conservation program as described in 29 CFR 1910.95(c) through (n) was not instituted when employee noise exposures equaled or exceeded an 8 hour time-weighted average sound level (TWA) of 85 dBA: a) AmTech Yarns, Inc, 21 Trade Drive Massena, NY 13662, Process Area, on or about 1/18/23: An operator, operating the nylon extrusion processing equipment was exposed to continuous noise at a level of 82.3% of the dose of the OSHA permissible exposure limit. The equivalent dBA for the 82.3% dose is approximately 88.6 dBA calculated as the 8-hour time weighted sound pressure level. The sampling was conducted on 1/18/23 for 472 minutes. Employee was wearing body guard ear plugs. Employer does not have hearing conservation program implemented. b) AmTech Yarns, Inc, 21 Trade Drive Massena, NY 13662, Process Area, on or about 1/18/23: A lead hand, operating the nylon extrusion processing equipment was exposed to continuous noise at a level of 110.0% of the dose of the OSHA permissible exposure limit. The equivalent dBA for the 110.0% dose is approximately 90.7 dBA calculated as the 8-hour time weighted sound pressure level. The sampling was conducted on 1/18/23 for 476 minutes. Employee was wearing body guard ear plugs. Employer does not have hearing conservation program implemented. Abatement methodology: Step 1: An effective hearing conservation program in accordance with 29 CFR 1910.95(c) through (n) shall be maintained. An effective hearing conservation program shall include, at a minimum: (1) A baseline audiogram for all employees exposed to noise levels equal to or in excess of the standard. (2) Annual audiograms for each overexposed employee. (3) Analysis of audiogram results with retesting and/or referral to an otolaryngologist or qualified physician when a significant threshold shift occurs. A significant shift will be considered to be equal to or greater than an average of 30 dba over the 2000, 3000, and 4000 hertz frequencies. (4) Where insert ear plugs or custom-molded devices are utilized, individual employee fitting shall be conducted by a trained person, and employees shall be instructed in the care and use of the devices.
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2023-03-28
Abatement Due Date 2024-02-15
Current Penalty 1500.0
Initial Penalty 3572.0
Contest Date 2023-04-12
Final Order 2024-01-29
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(1): The employer did not establish a program consisting of an energy control procedure, employee training and periodic inspections to ensure that before any employee performed any servicing or maintenance on a machine or equipment where the unexpected energizing, startup or release of stored energy could occur and cause injury, the machine or equipment shall be isolated from the energy source and rendered inoperative: a) The Chimney, AmTech Yarns, Inc, 21 Trade Drive Massena, NY 13662, on or about 12/28/22: The employer permitted servicing and maintenance activities on equipment including, but not limited to, cleaning the chute of the chimney while the process was actively running, without establishing a lockout/logout program inclusive of written energy control procedures, employee training, and periodic inspections, to prevent serious injuries from the unexpected energizing, start up or release of stored energy of the equipment. Abatement certification is required.
Citation ID 02001
Citaton Type Other
Standard Cited 19040040 A
Issuance Date 2023-03-28
Abatement Due Date 2024-02-15
Current Penalty 100.0
Initial Penalty 893.0
Contest Date 2023-04-12
Final Order 2024-01-29
Nr Instances 1
Nr Exposed 12
FTA Current Penalty 0.0
Citation text line 29 CFR 1904.40(a): The employer did not provide an authorized government representative the records within the four business hours. a) AmTech Yarns, Inc, 21 Trade Drive Massena, NY 13662, on or about 1/4/23, the employer did not provide the agency with its injury and illness logs within four business hours of its request. Abatement certification is required.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
9433457105 2020-04-15 0248 PPP 21 TRADE RD, MASSENA, NY, 13662
Loan Status Date 2021-09-24
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 63430
Loan Approval Amount (current) 63430
Undisbursed Amount 0
Franchise Name -
Lender Location ID 21442
Servicing Lender Name BMO Bank National Association
Servicing Lender Address 320 S Canal St, Chicago, IL, 60606
Rural or Urban Indicator R
Hubzone Y
LMI N
Business Age Description New Business or 2 years or less
Project Address MASSENA, SAINT LAWRENCE, NY, 13662-0001
Project Congressional District NY-21
Number of Employees 15
NAICS code 313310
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 21442
Originating Lender Name BMO Bank National Association
Originating Lender Address Chicago, IL
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 64283.26
Forgiveness Paid Date 2021-08-30

Date of last update: 24 Mar 2025

Sources: New York Secretary of State