Search icon

SKYLAND CONSTRUCTION LLC

Company Details

Name: SKYLAND CONSTRUCTION LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 05 Apr 2018 (7 years ago)
Entity Number: 5317500
ZIP code: 10512
County: Putnam
Place of Formation: New York
Address: 539 ROUTE 52, APT 7, CARMEL, NY, United States, 10512

DOS Process Agent

Name Role Address
VOLODYMER ZAKHARCHENKO DOS Process Agent 539 ROUTE 52, APT 7, CARMEL, NY, United States, 10512

Filings

Filing Number Date Filed Type Effective Date
180405010102 2018-04-05 ARTICLES OF ORGANIZATION 2018-04-05

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
342408622 0215000 2017-06-07 66 LEONARD STREET, NEW YORK, NY, 10013
Inspection Type Prog Related
Scope Complete
Safety/Health Safety
Close Conference 2017-06-07
Emphasis L: LOCALTARG
Case Closed 2018-02-09

Related Activity

Type Inspection
Activity Nr 1240819
Safety Yes
Type Inspection
Activity Nr 1240871
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260403 I02 I
Issuance Date 2017-10-11
Abatement Due Date 2017-10-17
Current Penalty 3549.0
Initial Penalty 5070.0
Final Order 2017-11-09
Nr Instances 2
Nr Exposed 13
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.403(i)(2)(i): Live parts of electric equipment operating at 50 volts or more were not guarded against accidental contact by cabinets or other forms of enclosures, nor by any of the means listed in subparagraphs (A) through (D) of this paragraph: a) At the jobsite, on or about 6/7/17: Wiring pulled to a hallway and un attended at the time of the inspection was live. This area was used as a temporary staging point for scaffold components and other material, and frequented by other workers carrying the same. b) At the jobsite, on or about 6/7/17: A temporary light was mounted onto the ceiling and powered with a cord that hung down into the passageway and was spliced and held together with wire nuts. Workers who frequented this passageway would duck underneath or to the side to avoid the spliced live wire.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260404 B01 I
Issuance Date 2017-10-11
Abatement Due Date 2017-10-17
Current Penalty 2027.9
Initial Penalty 2897.0
Final Order 2017-11-09
Nr Instances 1
Nr Exposed 13
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(i): Employer did not use either ground fault circuit interrupters as specified in paragraph (b)(1)(ii) of this section, or an assured equipment grounding conductor program as specified in paragraph (b)(1)(iii) of this section to protect employees on construction sites: a) At the jobsite, on or about 6/7/17: Workers were using a variety of power tools that were plugged into wall outlets. The standard wall outlets were not GFCI protected.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260452 W02
Issuance Date 2017-10-11
Current Penalty 2027.9
Initial Penalty 2897.0
Final Order 2017-11-09
Nr Instances 1
Nr Exposed 13
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(w)(2): Scaffold casters and wheels were not locked with positive wheel and/or wheel and swivel locks, or equivalent means, to prevent movement of the scaffold while the scaffold was used in a stationary manner: a) At the jobsite, on or about 6/7/17: Employees were working from Werner mobile scaffolds were the wheels were not locked out.

Date of last update: 24 Mar 2025