Filing Number Date Filed Type Effective Date
180423010331 2018-04-23 CERTIFICATE OF INCORPORATION 2018-04-23

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343185476 0214700 2018-05-25 10 CAPTAINS NECK LN, SOUTHAMPTON, NY, 11968
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2018-05-25
Emphasis L: FALL, P: FALL
Case Closed 2023-04-03

Related Activity

Type Inspection
Activity Nr 1330429
Safety Yes
Type Inspection
Activity Nr 1318550
Safety Yes
Type Inspection
Activity Nr 1319339
Safety Yes
Type Inspection
Activity Nr 1330772
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2018-07-31
Current Penalty 2010.0
Initial Penalty 2217.0
Final Order 2018-08-16
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there is a possible danger of head injury from impact, or from falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) Worksite, 10 Captains Neck Ln, Southampton, NY, 11968 - An employee was working directly under chimney flashing as it was being hoisted approximately 27 feet above the ground below without wearing head protection; on or about 05/25/2018. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E05 I
Issuance Date 2018-07-31
Abatement Due Date 2018-08-06
Current Penalty 2010.0
Initial Penalty 3880.0
Final Order 2018-08-16
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels did not have guardrail systems that comply with subpart M of this part -- Fall Protection: a) Worksite, 10 Captains Neck Ln, Southampton, NY - An employee was accessing the roof of a residential home by walking across a walkway from the fourth tier of a fabricated frame scaffold approximately 27 feet above the ground below without a guardrail system; on or about 05/25/2018. b) Worksite, 10 Captains Neck Ln, Southampton, NY - An employee was accessing the fabricated frame scaffold by walking across a walkway from the second story window sill approximately 15 feet above the ground below without a guardrail system; on or about 05/25/2018. Note: In addition to abatement certification the employer is required to submit abatement documentation for this item in accordance with 29 CFR 1903.19.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 G04 XV
Issuance Date 2018-07-31
Abatement Due Date 2018-08-06
Current Penalty 2010.0
Initial Penalty 2217.0
Final Order 2018-08-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(4)(xv): Crossbracing used in place of a midrail was unacceptable because the crossing point of two braces is between 20 inches (0.5 m) and 30 inches ((0.8 M) above the work platform or as a toprail when the crossing point of two braces is not between 20 inches (0.5 m) and 30 inches (0.8 m) above the work platform or as a toprail when the crossing point of two braces is between 38 inches (0.97 m) and 48 inches (1.3 m) above the work platform. The endpoints at each upright were more than 48 inches (1.3 m) apart. a) Worksite, roof on the south side of residential building - An employee was working from the fourth tier of a fabricated frame scaffold approximately 27 feet above the ground below without a midrail, on or about 5/25/2018. Note: The employer is required to submit abatement certification for this item in accordance with 29 CFR 1903.19.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260501 B13
Issuance Date 2018-07-31
Abatement Due Date 2018-08-06
Current Penalty 2010.0
Initial Penalty 2772.0
Final Order 2018-08-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(13): Each employee engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): a)Worksite, 10 Captains Neck Ln, Southampton, NY, 11968 - Employees were doing chimney work on the roof of a residential home, approximately 30 feet above the ground below without fall protection; on or about 05/25/2018. Note: Because abatement of this violation is already documented in the case file, the employer need not submit certification or documentation of abatement for this violation as normally required by CFR 1903.19.