Search icon

RMAC CONSTRUCTION CORP

Company Details

Name: RMAC CONSTRUCTION CORP
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 29 May 2018 (7 years ago)
Entity Number: 5349453
ZIP code: 11218
County: Kings
Place of Formation: New York
Address: 512 E 5TH STREET, BROOKLYN, NY, United States, 11218

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 512 E 5TH STREET, BROOKLYN, NY, United States, 11218

Filings

Filing Number Date Filed Type Effective Date
180529010637 2018-05-29 CERTIFICATE OF INCORPORATION 2018-05-29

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345633440 0215000 2021-11-10 512 E 5TH STREET, BROOKLYN, NY, 11218
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2021-11-10
Emphasis L: LOCALTARG
Case Closed 2022-04-08

Related Activity

Type Inspection
Activity Nr 1449213
Safety Yes
344492137 0215000 2019-12-05 4715 NEW UTRECHT AVE., BROOKLYN, NY, 11219
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-12-05
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B01
Issuance Date 2020-04-24
Abatement Due Date 2020-04-30
Current Penalty 2400.0
Initial Penalty 4048.0
Final Order 2020-07-01
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(1): Each platform on all working levels of scaffolds was not fully planked or decked between the front uprights and the guardrail supports as specified in paragraphs 1926.451(b)(1)(i)-(ii) Location: 4715 New Utrecht Ave. Brooklyn NY On or about: December 05, 2019 a) Employee performing façade work on a store front while on the fourth and third tier of a welded frame scaffold which was not fully planked
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 C01
Issuance Date 2020-04-24
Abatement Due Date 2020-04-30
Current Penalty 1400.0
Initial Penalty 2892.0
Final Order 2020-07-01
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(c)(1): Supported scaffolds with a height to base width (including outrigger supports, if used) ratio of more than four to one (4:1) were not restrained from tipping by guying, tying, bracing, or equivalent means, as set forth in subparagraphs (i) - (iii) of this paragraph. Location: 4715 New Utrecht Ave. Brooklyn NY On or about: December 05, 2019 a) Employees were working on a tubular welded frame scaffold that was approximately 24 ft. in height and was not restrained from tipping.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2020-04-24
Abatement Due Date 2020-04-30
Current Penalty 2400.0
Initial Penalty 4048.0
Final Order 2020-07-01
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Location: 4715 New Utrecht Ave. Brooklyn NY On or about: December 05, 2019 a) Employees utilized the cross braces of a tubular welded frame scaffold as means of access.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2020-04-24
Abatement Due Date 2020-04-30
Current Penalty 2400.0
Initial Penalty 4048.0
Final Order 2020-07-01
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: 4715 New Utrecht Ave. Brooklyn NY On or about: December 05, 2019 a) Employees working on the 3rd and 4th tiers of a tubular welded frame scaffold without being provided any fall protection.
Citation ID 01007A
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2020-04-24
Abatement Due Date 2020-05-06
Current Penalty 2400.0
Initial Penalty 2892.0
Final Order 2020-07-01
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work while on a scaffold trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used and to understand the procedures to control or minimize those hazards. Location: 4715 New Utrecht Ave. Brooklyn NY On or about: December 05, 2019 a) Employee was not trained to recognize hazards associated with scaffolds.
Citation ID 01007B
Citaton Type Serious
Standard Cited 19260451 F06
Issuance Date 2020-04-24
Abatement Due Date 2020-04-30
Current Penalty 0.0
Initial Penalty 4048.0
Final Order 2020-07-01
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(6): Scaffolds were erected, used, dismantled, altered, or moved such that they, or any conductive material handled on them, could have come closer than the minimum distances established for specific voltages as set forth in the table in subparagraph (f)(6).Note: Specify distances as indicated in table in paragraph (f)(6) of this section. Location: 4715 New Utrecht Ave. Brooklyn NY On or about: December 05, 2019 a) Employees working on a tubular welded frame baler scaffold that was erected within 3 feet of an electrical service drop.

Date of last update: 23 Mar 2025

Sources: New York Secretary of State