Filing Number Date Filed Type Effective Date
180531010146 2018-05-31 CERTIFICATE OF INCORPORATION 2018-05-31

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343375176 0213600 2018-08-02 77 CATTARAUGUS STREET, SPRINGVILLE, NY, 14141
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2018-08-02
Emphasis P: FALL, L: FALL
Case Closed 2023-05-09

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260100 A
Issuance Date 2018-09-11
Current Penalty 1663.0
Initial Penalty 1663.0
Final Order 2018-10-05
Nr Instances 1
Nr Exposed 2
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: a) On or about 8/2/18 at a roof project located at 77 Cattaraugus Street, Springville, New York; employees working on the ground below active roof operations were not wearing hard hats. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2018-09-11
Current Penalty 2217.0
Initial Penalty 2217.0
Final Order 2018-10-05
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 8/2/18 at a roof project located at 77 Cattaraugus Street, Springville, New York; employees were placing shingles on the roof of a two story house. The roof had a 10 in 12 pitch and an eave height of approximately 10 feet. There was no fall protection in use. NO ABATEMENT CERTIFICATION REQUIRED