OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344216130 0213100 2019-08-08 5 SARATOGA AVE, ROUND LAKE, NY, 12151
Inspection Type Prog Other
Scope Complete
Safety/Health Safety
Close Conference 2019-08-08
Emphasis P: FALL, L: FALL
Case Closed 2022-07-21

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-09-24
Current Penalty 1449.0
Initial Penalty 1449.0
Final Order 2019-10-21
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee used appropriate eye or face protection when exposed to eye or face hazards from flying particles. (a) Front of the building: On or prior 8/8/19, while installing siding and trim, employees were operating pneumatic nail guns, saws, and a 4" angle grinder without use of eye protection.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2019-09-24
Current Penalty 1449.0
Initial Penalty 1449.0
Final Order 2019-10-21
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Complaint
Gravity 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. (a) Front of building: On or prior to 8/08/19, employees were installing siding and trim from a pump-jack scaffold platform at a height of approximately 12' above the ground; scaffold was not equipped with a mid-rail and end rail protection.