Search icon

EMPIRE BUILDERS OF CNY, INC.

Company Details

Name: EMPIRE BUILDERS OF CNY, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 24 Jul 2018 (7 years ago)
Entity Number: 5381145
ZIP code: 13069
County: Oswego
Place of Formation: New York
Address: 1419 COUNTY ROUTE 57, FULTON, NY, United States, 13069

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
EMPIRE BUILDERS OF CNY, INC. DOS Process Agent 1419 COUNTY ROUTE 57, FULTON, NY, United States, 13069

Filings

Filing Number Date Filed Type Effective Date
180724010311 2018-07-24 CERTIFICATE OF INCORPORATION 2018-07-24

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
343993069 0215800 2019-05-07 1603 WEST GENESEE STREET, SYRACUSE, NY, 13204
Inspection Type Planned
Scope Complete
Safety/Health Safety
Close Conference 2019-05-07
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260102 A01
Issuance Date 2019-06-07
Current Penalty 2273.0
Initial Penalty 2273.0
Contest Date 2019-08-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee was using eye protection when exposed to eye or face hazards from flying particles: a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was cutting wood trim while using a compound miter saw, without eye protection. a) 1603 West Genesee Street, northeast corner of building, on or about 5-7-19: One employee was fastening wood trim with the use of a pneumatic nailer, without eye protection.
Citation ID 01002A
Citaton Type Serious
Standard Cited 19260304 F
Issuance Date 2019-06-07
Abatement Due Date 2019-06-17
Current Penalty 2842.0
Initial Penalty 2842.0
Contest Date 2019-08-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was ripping wood trim using a table saw that was not equipped with a spreader. b) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was ripping wood trim using a table saw that was not equipped with non kick-back fingers or "dogs". c) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was ripping wood trim using a table saw that was not equipped with a magnetic switch or anti-restart device. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Citation ID 01002B
Citaton Type Serious
Standard Cited 19260304 I
Issuance Date 2019-06-07
Abatement Due Date 2019-06-17
Current Penalty 0.0
Initial Penalty 0.0
Contest Date 2019-08-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was ripping wood trim using a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM
Citation ID 01003
Citaton Type Serious
Standard Cited 19260404 B01 II
Issuance Date 2019-06-07
Abatement Due Date 2019-06-17
Current Penalty 2842.0
Initial Penalty 2842.0
Contest Date 2019-08-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was operating power tools (miter saw, table saw), powered through an extension cord and receptacle that was not protected by a ground fault circuit interrupter (GFCI).
Citation ID 01004
Citaton Type Serious
Standard Cited 19260405 G02 IV
Issuance Date 2019-06-07
Abatement Due Date 2019-06-17
Current Penalty 2842.0
Initial Penalty 2842.0
Contest Date 2019-08-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was operating power tools (miter saw, table saw), powered through an extension cord that exhibited a broken strain relief.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260453 B02 V
Issuance Date 2019-06-07
Abatement Due Date 2019-06-17
Current Penalty 2842.0
Initial Penalty 2842.0
Contest Date 2019-08-09
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: a) 1603 West Genesee Street, northeast corner of building, on or about 5-7-19: One employee was working while in an articulating, extensible boom, aerial lift, without a safety harness or body belt, exposing the employee to a fall hazard of 15 feet 6 inches.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
8576967010 2020-04-08 0248 PPP 1419 COUNTY ROUTE 57, FULTON, NY, 13069-4521
Loan Status Date 2021-08-12
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 37197
Loan Approval Amount (current) 37197
Undisbursed Amount 0
Franchise Name -
Lender Location ID 292450
Servicing Lender Name Pathfinder Bank
Servicing Lender Address 214 W 1st St, OSWEGO, NY, 13126-2550
Rural or Urban Indicator R
Hubzone N
LMI N
Business Age Description New Business or 2 years or less
Project Address FULTON, OSWEGO, NY, 13069-4521
Project Congressional District NY-24
Number of Employees 6
NAICS code 238390
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 292450
Originating Lender Name Pathfinder Bank
Originating Lender Address OSWEGO, NY
Gender Male Owned
Veteran Unanswered
Forgiveness Amount 37665.78
Forgiveness Paid Date 2021-07-22

Date of last update: 06 Mar 2025

Sources: New York Secretary of State