Inspection Type |
Planned
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2019-05-07
|
Emphasis |
L: FALL, P: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260102 A01 |
Issuance Date |
2019-06-07 |
Current Penalty |
2273.0 |
Initial Penalty |
2273.0 |
Contest Date |
2019-08-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.102(a)(1): The employer did not ensure that each affected employee was using eye protection when exposed to eye or face hazards from flying particles: a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was cutting wood trim while using a compound miter saw, without eye protection. a) 1603 West Genesee Street, northeast corner of building, on or about 5-7-19: One employee was fastening wood trim with the use of a pneumatic nailer, without eye protection. |
|
Citation ID |
01002A |
Citaton Type |
Serious |
Standard Cited |
19260304 F |
Issuance Date |
2019-06-07 |
Abatement Due Date |
2019-06-17 |
Current Penalty |
2842.0 |
Initial Penalty |
2842.0 |
Contest Date |
2019-08-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(f) Section 4.1.2(b) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws were not equipped with a spreader to prevent material from squeezing the saw or being thrown back on the operator: 29 CFR 1926.304(f) Section 4.1.2(c) American National Standards Institute 01.1-1961, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Circular hand-fed rip saws did not have non-kickback fingers or dogs so located as to oppose the thrust or tendency of the saw to pick up the material or to throw it back toward the operator: 29 CFR 1926.304(f) Section 5.1.3.3 American National Standards Institute 01.1-1975, Safety Code for Woodworking Machinery as adopted by 29 CFR 1926.304(f): Electrically driven equipment was not equipped with magnetic switches or other devices that will prevent automatic restarting of the machine after a power failure: a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was ripping wood trim using a table saw that was not equipped with a spreader. b) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was ripping wood trim using a table saw that was not equipped with non kick-back fingers or "dogs". c) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was ripping wood trim using a table saw that was not equipped with a magnetic switch or anti-restart device. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |
|
Citation ID |
01002B |
Citaton Type |
Serious |
Standard Cited |
19260304 I |
Issuance Date |
2019-06-07 |
Abatement Due Date |
2019-06-17 |
Current Penalty |
0.0 |
Initial Penalty |
0.0 |
Contest Date |
2019-08-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.304(i)(1): Each circular had-fed ripsaw was not guarded by a hood which completely enclosed that portion of the saw above the table and that portion of the saw above the material being cut: a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was ripping wood trim using a table saw that was not equipped with a hood guard that automatically adjusts to enclose the saw blade. ABATEMENT CERTIFICATION IS REQUIRED FOR THIS ITEM |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260404 B01 II |
Issuance Date |
2019-06-07 |
Abatement Due Date |
2019-06-17 |
Current Penalty |
2842.0 |
Initial Penalty |
2842.0 |
Contest Date |
2019-08-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.404(b)(1)(ii): On a construction site, where an assured equipment grounding program was not utilized, all 120-volt, single-phase, 15 and 20 ampere receptacle outlets which were not a part of the permanent wiring of the building or structure and which are in use by employees did not have approved ground fault circuit interrupters for personal protection: a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was operating power tools (miter saw, table saw), powered through an extension cord and receptacle that was not protected by a ground fault circuit interrupter (GFCI). |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260405 G02 IV |
Issuance Date |
2019-06-07 |
Abatement Due Date |
2019-06-17 |
Current Penalty |
2842.0 |
Initial Penalty |
2842.0 |
Contest Date |
2019-08-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.405(g)(2)(iv): Flexible cords were not connected to devices and fittings so that strain relief is provided to prevent pull from being directly transmitted to joints or terminal screws: a) 1603 West Genesee Street, north side of building, front porch, on or about 5-7-19: One employee was operating power tools (miter saw, table saw), powered through an extension cord that exhibited a broken strain relief. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19260453 B02 V |
Issuance Date |
2019-06-07 |
Abatement Due Date |
2019-06-17 |
Current Penalty |
2842.0 |
Initial Penalty |
2842.0 |
Contest Date |
2019-08-09 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.453(b)(2)(v): A body belt was not worn and/or a lanyard was not attached to the boom or basket when working from an aerial lift: a) 1603 West Genesee Street, northeast corner of building, on or about 5-7-19: One employee was working while in an articulating, extensible boom, aerial lift, without a safety harness or body belt, exposing the employee to a fall hazard of 15 feet 6 inches. |
|
|