Search icon

JND HOME IMPROVEMENTS, LLC

Company Details

Name: JND HOME IMPROVEMENTS, LLC
Jurisdiction: New York
Legal type: DOMESTIC LIMITED LIABILITY COMPANY
Status: Active
Date of registration: 02 Aug 2018 (7 years ago)
Entity Number: 5386470
ZIP code: 11764
County: Suffolk
Place of Formation: New York
Address: P.O. BOX 233, MILLER PLACE, NY, United States, 11764

DOS Process Agent

Name Role Address
THE LLC DOS Process Agent P.O. BOX 233, MILLER PLACE, NY, United States, 11764

Filings

Filing Number Date Filed Type Effective Date
180926000578 2018-09-26 CERTIFICATE OF PUBLICATION 2018-09-26
180802010148 2018-08-02 ARTICLES OF ORGANIZATION 2018-08-02

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
340048529 0213600 2014-10-30 9067 OTTO - EAST OTTO ROAD, OTTO, NY, 14766
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2014-10-30
Emphasis L: FALL, P: FALL
Case Closed 2016-07-11

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 G01 I
Issuance Date 2014-12-03
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2014-12-18
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(i): Each employee on a boatswains' chair, catenary scaffold, float scaffold, needle beam scaffold, or ladder jack scaffold was not protected by a personal fall arrest system: a) On or about 10/30/14 at residential roof replacement at 9067 Otto - East Otto Road, Otto, New York; employees were using a ladder jack scaffold while tearing off shingles. Employee were not using personal fall arrest system. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19260501 B11
Issuance Date 2014-12-03
Current Penalty 1000.0
Initial Penalty 2000.0
Final Order 2014-12-18
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.501(b)(11): Each employee on a steep roof with unprotected sides and edges 6 feet (1.8 m) or more above lower levels was not protected from falling by guardrail systems with toeboards, safety net systems, or personal fall arrest systems: a) On or about 10/30/14 at residential roof replacement at 9067 Otto - East Otto Road, Otto, New York; employees were replacing a roof on a house that had a roof pitch of 12 in 12 with eave heights of approximately 10 and 18 feet. There was no fall protection in place. NO ABATEMENT CERTIFICATION REQUIRED
Citation ID 01003
Citaton Type Serious
Standard Cited 19261053 B01
Issuance Date 2014-12-03
Current Penalty 800.0
Initial Penalty 1600.0
Final Order 2014-12-18
Nr Instances 1
Nr Exposed 4
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface and the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface to which the ladder was used to gain access: a) On or about 10/30/14 at residential roof replacement at 9067 Otto - East Otto Road, Otto, New York; employees were using an extension ladder to access the work area on the roof. The ladder extended 1 foot above the landing surface. NO ABATEMENT CERTIFICATION REQUIRED

Date of last update: 23 Mar 2025

Sources: New York Secretary of State