Search icon

J. L. BRIDGEVIEW CONSTRUCTION COMPANY, INC.

Company Details

Name: J. L. BRIDGEVIEW CONSTRUCTION COMPANY, INC.
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 17 Aug 2018 (7 years ago)
Entity Number: 5395473
ZIP code: 12487
County: Ulster
Place of Formation: New York
Address: 189 LINDORF STREET, ULSTER PARK, NY, United States, 12487

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 189 LINDORF STREET, ULSTER PARK, NY, United States, 12487

History

Start date End date Type Value
2024-06-05 2024-08-27 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2024-05-09 2024-06-05 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2023-10-13 2024-05-09 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2023-06-21 2023-10-13 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2023-02-23 2023-06-21 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-12-21 2023-02-23 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-10-03 2022-12-21 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-04-28 2022-10-03 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2022-03-29 2022-04-28 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2021-11-16 2022-03-29 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
180817010329 2018-08-17 CERTIFICATE OF INCORPORATION 2018-08-17

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
344558234 0213100 2020-01-10 WASHINGTON AVE, KINGSTON, NY, 12401
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2020-01-10
Emphasis N: TRENCH, P: TRENCH
Case Closed 2025-02-07

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19260651 C02
Issuance Date 2020-03-27
Abatement Due Date 2020-04-02
Current Penalty 2892.0
Initial Penalty 2892.0
Final Order 2020-04-21
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(c)(2): A stairway, ladder, ramp or other safe means of egress was not located in trench excavations that were 4 feet (1.22m) or more in depth so as to require no more than 25 feet (7.62m) of lateral travel for employees: a) Worksite - On or prior to January 10, 2020, employees working in an approximately 15 feet deep trench had to walk the approximate 135 feet length of the trench to exit at the other end of the trench without the use of a ladder, ramp or other safe means of egress.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19261053 B04
Issuance Date 2020-03-27
Abatement Due Date 2020-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-04-21
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1053(b)(4): Ladder(s) were used for purposes other than the purpose for which they were designed: a) Worksite - On or about January 9, 2020, an employee was exposed to fall hazards of approximately 5 feet 9 inches due to using a 5 foot 9 inch Werner self-supporting ladder as a non-self support ladder to get in and out of a trench.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260651 J02
Issuance Date 2020-03-27
Abatement Due Date 2020-04-02
Current Penalty 4048.0
Initial Penalty 4048.0
Final Order 2020-04-21
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(j)(2): Protection was not provided by placing and keeping excavated or other materials or equipment at least 2 feet (.61m) from the edge of excavations, or by the use of retaining devices that were sufficient to prevent materials or equipment from falling or rolling into excavations, or by a combination of both if necessary: a) Worksite - On or prior to January 10, 2020, spoil-piles approximately 10 feet high were placed right on the edge of the approximately 15 feet deep trench exposing employees to cave-in hazards.
Citation ID 01003A
Citaton Type Serious
Standard Cited 19260651 K01
Issuance Date 2020-03-27
Abatement Due Date 2020-04-02
Current Penalty 2892.0
Initial Penalty 2892.0
Final Order 2020-04-21
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(k)(1): Daily inspections of excavations, the adjacent areas, and protective systems were not made by a competent person for evidence of a situation that could have resulted in possible cave-ins, indications of failure of protective systems: a) Worksite - On or prior to January 10, 2020, daily inspections of the trench were not made by a competent person exposing employees to cave-in hazards.
Citation ID 01003B
Citaton Type Serious
Standard Cited 19260651 K02
Issuance Date 2020-03-27
Abatement Due Date 2020-04-02
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2020-04-21
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.651(k)(2): Where the competent person found evidence of a situation that could result in a possible cave-in, indications of failure of protective systems, hazardous atmospheres, or other hazardous conditions, exposed employees were not removed from the hazardous area until the necessary precautions have been taken to ensure their safety: a) Worksite - On or about January 10, 2020, the competent person did not remove exposed employees from the hazardous area inside the trench until the necessary precautions were taken.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260652 A01
Issuance Date 2020-03-27
Abatement Due Date 2020-04-02
Current Penalty 4048.0
Initial Penalty 4048.0
Final Order 2020-04-21
Nr Instances 1
Nr Exposed 2
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.652(a)(1): Each employee in an excavation was not protected from cave-ins by an adequate protective system designed in accordance with 29 CFR 1926.652 (b) or (c): a) Worksite - On or prior to January 10, 2020, employees were exposed to caught-in hazards due to working in an approximately 15 feet deep trench without cave-in protection in place.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
6016358003 2020-06-29 0202 PPP 189 LINDORF ST, ULSTER PARK, NY, 12487-5009
Loan Status Date 2021-07-15
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 9500
Loan Approval Amount (current) 9500
Undisbursed Amount 0
Franchise Name -
Lender Location ID 47130
Servicing Lender Name The Bank of Greene County
Servicing Lender Address 302 Main St, CATSKILL, NY, 12414-1801
Rural or Urban Indicator R
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address ULSTER PARK, ULSTER, NY, 12487-5009
Project Congressional District NY-18
Number of Employees 1
NAICS code 236220
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 47130
Originating Lender Name The Bank of Greene County
Originating Lender Address CATSKILL, NY
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 9588.67
Forgiveness Paid Date 2021-06-02

Date of last update: 06 Mar 2025

Sources: New York Secretary of State