Search icon

YANKY'S HVAC CORP

Company Details

Name: YANKY'S HVAC CORP
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 20 Aug 2018 (7 years ago)
Entity Number: 5395854
ZIP code: 10956
County: Rockland
Place of Formation: New York
Address: 468 ny-304, NEW CITY, NY, United States, 10956
Principal Address: 3 Perth Ave, Spring Valley, NY, United States, 10977

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

Chief Executive Officer

Name Role Address
YAKOV TURIM Chief Executive Officer 3 PERTH AVE, SPRING VALLEY, NY, United States, 10977

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 468 ny-304, NEW CITY, NY, United States, 10956

History

Start date End date Type Value
2024-08-01 2024-08-01 Address 3 PERTH AVE, SPRING VALLEY, NY, 10977, USA (Type of address: Chief Executive Officer)
2023-02-09 2024-08-01 Address 3 PERTH AVE, SPRING VALLEY, NY, 10977, USA (Type of address: Chief Executive Officer)
2023-02-09 2024-08-01 Address 468 ny-304, NEW CITY, NY, 10956, USA (Type of address: Service of Process)
2023-02-08 2024-08-01 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2018-08-20 2023-02-08 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2018-08-20 2023-02-09 Address 3 PERTH AVE, SPRING VALLEY, NY, 10977, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
240801034924 2024-08-01 BIENNIAL STATEMENT 2024-08-01
230209000316 2023-02-08 CERTIFICATE OF CHANGE BY ENTITY 2023-02-08
220920001330 2022-09-20 BIENNIAL STATEMENT 2022-08-01
180820010156 2018-08-20 CERTIFICATE OF INCORPORATION 2018-08-20

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347638215 0216000 2024-07-23 59 RTE. 59, MONSEY, NY, 10952
Inspection Type Referral
Scope Partial
Safety/Health Safety
Close Conference 2024-07-23
Case Closed 2025-01-24

Related Activity

Type Referral
Activity Nr 2190962
Safety Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100023 B09
Issuance Date 2024-07-26
Current Penalty 3457.0
Initial Penalty 3457.0
Final Order 2024-08-22
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(b)(9): The employer did not ensure that ladders are inspected before initial use in each work shift, and more frequently as necessary, to identify any visible defects that could cause employee injury. location: exterior of building on or about:7/23/24 a) Employees were using a Gorilla ladder, that was missing a rung, to access the roof. The ladder was not inspected for defects. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100023 B10
Issuance Date 2024-07-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-22
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Referral
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(b)(10): 29 CFR 1910.23(b)(10): The employer did not ensure that any ladder with structural or other defects as immediately tagged "Dangerous: Do Not Use" or with similar language in accordance with � 1910.145 and removed from service until repaired in accordance with � 1910.22(d), or replaced. location: exterior of building on or about:7/23/24 a) Employees were using a Gorilla ladder, that was missing a rung, to access the roof. The ladder was not immediately tagged nor removed from service. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.
Citation ID 01001C
Citaton Type Serious
Standard Cited 19100023 C11
Issuance Date 2024-07-26
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2024-08-22
Nr Instances 1
Nr Exposed 3
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.23(c)(11): 29 CFR 1910.23(c)(11): The employer did not ensure that portable ladders used to gain access to an upper landing surface that have side rails that extend at least 3 feet (0.9 m) above the upper landing surface. location: exterior of building on or about:7/23/24 a) Employees were using a Gorilla ladder, that was missing a rung, to access the roof. The ladder only extended 6' above the upper landing. NOTE: Because abatement of this violation is already documented in the inspection casefile, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19.

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
1492968007 2020-06-22 0202 PPP 3 PERTH AVE, SPRING VALLEY, NY, 10977-7217
Loan Status Date 2021-11-18
Loan Status Paid in Full
Loan Maturity in Months 60
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 5416.66
Loan Approval Amount (current) 5416.66
Undisbursed Amount 0
Franchise Name -
Lender Location ID 456756
Servicing Lender Name Cross River Bank
Servicing Lender Address 885 Teaneck Rd, TEANECK, NJ, 07666-4546
Rural or Urban Indicator U
Hubzone N
LMI N
Business Age Description Unanswered
Project Address SPRING VALLEY, ROCKLAND, NY, 10977-7217
Project Congressional District NY-17
Number of Employees 1
NAICS code 238220
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Corporation
Originating Lender ID 456756
Originating Lender Name Cross River Bank
Originating Lender Address TEANECK, NJ
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 5488.49
Forgiveness Paid Date 2021-10-25

Date of last update: 23 Mar 2025

Sources: New York Secretary of State