Name: | NK STAR CONSTRUCTION, LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 07 Sep 2018 (7 years ago) |
Entity Number: | 5406629 |
ZIP code: | 14086 |
County: | Erie |
Place of Formation: | New York |
Address: | 2 WENDLING COURT, LANCASTER, NY, United States, 14086 |
Name | Role | Address |
---|---|---|
C/O THE LIMITED LIABILITY COMPANY | DOS Process Agent | 2 WENDLING COURT, LANCASTER, NY, United States, 14086 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
181120000871 | 2018-11-20 | CERTIFICATE OF PUBLICATION | 2018-11-20 |
180907010535 | 2018-09-07 | ARTICLES OF ORGANIZATION | 2018-09-07 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345954051 | 0213600 | 2022-05-12 | 240 NIAGARA STREET BUILDING 9, BUFFALO, NY, 14202 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Inspection |
Activity Nr | 1595407 |
Safety | Yes |
Inspection Type | Planned |
Scope | Partial |
Safety/Health | Safety |
Close Conference | 2021-04-08 |
Emphasis | L: FALL, P: FALL |
Case Closed | 2023-10-11 |
Related Activity
Type | Inspection |
Activity Nr | 1526761 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1525223 |
Safety | Yes |
Type | Inspection |
Activity Nr | 1526768 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260453 B02 V |
Issuance Date | 2021-07-30 |
Current Penalty | 1000.0 |
Initial Penalty | 3901.0 |
Contest Date | 2021-08-25 |
Final Order | 2022-05-13 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.453(b)(2)(v): A safety harness with lanyard attached to the boom or basket was not worn by employee(s) working from an aerial lift: a) On or about 4/8/2021 at a project located at 200 Niagara Street, Buffalo, New York; employees were using a boom lift to access work areas while performing installing sheathing on the front of the building. The employees in the lift did not have harnesses with lanyards attached to the boom or basket. NO ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B01 |
Issuance Date | 2021-07-30 |
Current Penalty | 1000.0 |
Initial Penalty | 3901.0 |
Contest Date | 2021-08-25 |
Final Order | 2022-05-13 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(1): Each employee on a walking/working surface with an unprotected side or edge which was 6 feet (1.8 m) or more above a lower level was not protected from falling by the use of guardrail systems, safety net systems, or personal fall arrest systems: a) On or about 4/8/2021 at a project located at 200 Niagara Street, Buffalo, New York; employees were installing windows on a 2 story building. Employees were working from the porch roof with a fall height of approximately 12 feet. There were no fall protection measures in place. NO ABATEMENT CERTIFICATION REQUIRED |