Name: | EDDY CONSTRUCTION ROOFING & SIDING LLC |
Jurisdiction: | New York |
Legal type: | DOMESTIC LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 01 Nov 2018 (6 years ago) |
Entity Number: | 5436038 |
ZIP code: | 10573 |
County: | Westchester |
Place of Formation: | New York |
Address: | 29 ELMONT AVE # 2, PORT CHESTER, NY, United States, 10573 |
Name | Role | Address |
---|---|---|
EDDY CONSTRUCTION ROOFING & SIDING LLC | DOS Process Agent | 29 ELMONT AVE # 2, PORT CHESTER, NY, United States, 10573 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
181101010045 | 2018-11-01 | ARTICLES OF ORGANIZATION | 2018-11-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
345108708 | 0216000 | 2021-01-21 | 308 MAYFLOWER AVENUE, NEW ROCHELLE, NY, 10801 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260100 A |
Issuance Date | 2021-04-13 |
Current Penalty | 1100.0 |
Initial Penalty | 1755.0 |
Final Order | 2021-04-26 |
Nr Instances | 1 |
Nr Exposed | 1 |
Gravity | 1 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.100(a): Employees working in areas where there was a possible danger of head injury from impact, or falling or flying objects, or from electrical shock and burns, were not protected by protective helmets: A) Exterior, On the ground: An employee was exposed to head injuries while working below roofing activities. The employee was not protected by a hard hat or protective helmet, on or about January 21st, 2021. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2021-04-13 |
Current Penalty | 2567.0 |
Initial Penalty | 4096.0 |
Final Order | 2021-04-26 |
Nr Instances | 1 |
Nr Exposed | 2 |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): A) Roof of the structure: Employees were exposed to fall hazards of approximately 19 feet while engaged in roofing work on the roof of a structure without a means of fall protection in place, on or about January 21st, 2021. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2021-04-13 |
Current Penalty | 1833.0 |
Initial Penalty | 2926.0 |
Final Order | 2021-04-26 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Where portable ladders were used for access to an upper landing surface and the ladder's length allows, the ladder side rails did not extend at least 3 feet (.9 m) above the upper landing surface being accessed: A) Exterior, Front of the house: Employees were exposed to fall hazards of approximately 19 feet while using an extension ladder that was not extended at least 3 feet over the landing that they were accessing, on or about January 21st, 2021. NOTE: Because abatement of this violation is already documented in the inspection case file, the employer need not submit certification or documentation of abatement for this violation as normally required by 29 CFR 1903.19. |
Date of last update: 23 Mar 2025
Sources: New York Secretary of State