Search icon

STEEL & O'BRIEN MANUFACTURING, INC.

Company Details

Name: STEEL & O'BRIEN MANUFACTURING, INC.
Jurisdiction: New York
Legal type: FOREIGN BUSINESS CORPORATION
Status: Active
Date of registration: 15 Nov 2018 (6 years ago)
Entity Number: 5443789
ZIP code: 14009
County: Wyoming
Place of Formation: Delaware
Principal Address: 5219 Mulhauser Road, West Chester, OH, United States, 45011
Address: 7869 Route 98, Arcade, NY, United States, 14009

DOS Process Agent

Name Role Address
C T CORPORATION SYSTEM DOS Process Agent 7869 Route 98, Arcade, NY, United States, 14009

Chief Executive Officer

Name Role Address
SCOTT KERNS Chief Executive Officer 5219 MULHAUSER ROAD, WEST CHESTER, OH, United States, 45011

History

Start date End date Type Value
2024-11-01 2024-11-01 Address 5219 MULHAUSER ROAD, WEST CHESTER, OH, 45011, USA (Type of address: Chief Executive Officer)
2019-05-14 2024-11-01 Address 28 LIBERTY ST., NEW YORK, NY, 10005, USA (Type of address: Service of Process)
2018-11-15 2019-05-14 Address 111 EIGHTH AVENUE, NEW YORK, NY, 10011, USA (Type of address: Service of Process)

Filings

Filing Number Date Filed Type Effective Date
241101033557 2024-11-01 BIENNIAL STATEMENT 2024-11-01
221102002710 2022-11-02 BIENNIAL STATEMENT 2022-11-01
SR-109818 2019-05-14 CERTIFICATE OF CHANGE (BY AGENT) 2019-05-14
181127000519 2018-11-27 CERTIFICATE OF AMENDMENT 2018-11-27
181115000166 2018-11-15 APPLICATION OF AUTHORITY 2018-11-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
347016503 0213600 2023-10-05 7869 NEW YORK ROUTE 98, ARCADE, NY, 14009
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2023-10-05
Emphasis N: AMPUTATE, P: AMPUTATE
Case Closed 2024-12-12

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100147 C04 II B
Issuance Date 2023-10-20
Abatement Due Date 2023-11-14
Current Penalty 5100.0
Initial Penalty 10046.0
Final Order 2023-11-16
Nr Instances 1
Nr Exposed 15
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(c)(4)(ii)(B):The energy control procedures did not clearly and specifically outline the steps for shutting down, isolating, blocking and securing machines or equipment to control hazardous energy: a) On or about 10/05/2023 throughout establishment where employees operate machines such as, but not limited to: CNC machines, horizontal band saws and the energy control procedures did not identify the magnitude of the energy sources and the specific energy isolating means for controlling energy were not identified. Also, generic statements such as "release any stored energy" and "go to the bus bar and pull disconnect off for the required machine" were used in the procedures without identifying whether there was a potential for stored energy and the means necessary for releasing the stored energy, or identifying the appropriate bus bar disconnect. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100147 D04 I
Issuance Date 2023-10-20
Abatement Due Date 2023-11-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-11-16
Nr Instances 1
Nr Exposed 15
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.147(d)(4)(i): Lockout or tagout devices were not affixed to each energy isolating device by authorized employees: a) On or about 10/05/2023 in the manufacturing areas; where employees performing servicing/maintenance on horizontal band saws did not unplug the machines(and control the plug) while performing servicing/maintenance such as changing the blade on the band saws. Also, the documented energy control procedures for some pieces of equipment such as, but not limited to CNC machines directed the authorized employee to "go to the bus bar and pull disconnect off for the required machine". The employees performing the servicing and maintenance were not utilizing the bus bar for deenergizing the machines. ABATEMENT CERTIFICATION REQUIRED
Citation ID 01002
Citaton Type Serious
Standard Cited 19100151 C
Issuance Date 2023-10-20
Abatement Due Date 2023-11-14
Current Penalty 5100.0
Initial Penalty 10046.0
Final Order 2023-11-16
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.151(c):Where employees were exposed to injurious corrosive materials, suitable facilities for quick drenching or flushing of the eyes and body were not provided within the work area for immediate emergency use: a) On or about 10/05/2023 in the parts wash area; where employees were exposed to GILLITE 0650, a corrosive chemical, in the parts washer. The SDS for the material states "flush with running water for at least 15 minutes". The only eye wash/drench facilities in the immediate area was a one liter squeeze bottle of saline solution. ABATEMENT CERTIFICATION REQUIRED
Citation ID 02001
Citaton Type Other
Standard Cited 19100303 B02
Issuance Date 2023-10-20
Abatement Due Date 2023-11-14
Current Penalty 0.0
Initial Penalty 0.0
Final Order 2023-11-16
Nr Instances 1
Nr Exposed 1
FTA Current Penalty 0.0
Citation text line 29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 10/06/2023 in the machining area by the MAZAK VTC-200C CNC machine; where standard duty metal, duplex receptacle boxes were used at the end of a flexible cord in a pendant application. The standard duty metal, duplex receptacle box is only approved for applications where the box is mounted in place. ABATEMENT CERTIFICATION REQUIRED
305721110 0213600 2002-10-01 12850 ROUTE 39, SARDINIA, NY, 14134
Inspection Type Complaint
Scope Partial
Safety/Health Safety
Close Conference 2002-11-07
Case Closed 2003-03-14

Related Activity

Type Complaint
Activity Nr 203729066
Safety Yes
Health Yes

Violation Items

Citation ID 01001A
Citaton Type Serious
Standard Cited 19100132 D01
Issuance Date 2002-12-06
Abatement Due Date 2003-01-08
Current Penalty 410.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 9
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01001B
Citaton Type Serious
Standard Cited 19100132 D01 I
Issuance Date 2002-12-06
Abatement Due Date 2003-01-08
Nr Instances 1
Nr Exposed 9
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01002
Citaton Type Serious
Standard Cited 19100136 A
Issuance Date 2002-12-06
Abatement Due Date 2002-12-24
Current Penalty 410.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 9
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01003
Citaton Type Serious
Standard Cited 19100147 C01
Issuance Date 2002-12-06
Abatement Due Date 2002-12-11
Current Penalty 410.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 8
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01004
Citaton Type Serious
Standard Cited 19100151 C
Issuance Date 2002-12-06
Abatement Due Date 2002-12-24
Current Penalty 540.0
Initial Penalty 1000.0
Nr Instances 1
Nr Exposed 1
Related Event Code (REC) Complaint
Gravity 02
Citation ID 01005A
Citaton Type Serious
Standard Cited 19100178 L06
Issuance Date 2002-12-06
Abatement Due Date 2003-01-08
Current Penalty 410.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01005B
Citaton Type Serious
Standard Cited 19100178 P01
Issuance Date 2002-12-06
Abatement Due Date 2002-12-11
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01006
Citaton Type Serious
Standard Cited 19100212 A01
Issuance Date 2002-12-06
Abatement Due Date 2002-12-11
Current Penalty 410.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 9
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01007A
Citaton Type Serious
Standard Cited 19101200 E01
Issuance Date 2002-12-06
Abatement Due Date 2002-12-11
Current Penalty 410.0
Initial Penalty 750.0
Nr Instances 1
Nr Exposed 8
Related Event Code (REC) Complaint
Gravity 01
Citation ID 01007B
Citaton Type Serious
Standard Cited 19101200 H01
Issuance Date 2002-12-06
Abatement Due Date 2003-01-08
Nr Instances 1
Nr Exposed 9
Related Event Code (REC) Complaint
Gravity 02

Paycheck Protection Program

Loan Number Loan Funded Date SBA Origination Office Code Loan Delivery Method Borrower Street Address
5640327008 2020-04-06 0296 PPP 7869 ROUTE 98, ARCADE, NY, 14009-9601
Loan Status Date 2020-12-08
Loan Status Paid in Full
Loan Maturity in Months 24
SBA Guaranty Percentage 100
Loan Approval Amount (at origination) 969000
Loan Approval Amount (current) 969000
Undisbursed Amount 0
Franchise Name -
Lender Location ID 75967
Servicing Lender Name Hiawatha National Bank
Servicing Lender Address N1555 770th St, HAGER CITY, WI, 54014-8027
Rural or Urban Indicator R
Hubzone N
LMI N
Business Age Description Existing or more than 2 years old
Project Address ARCADE, WYOMING, NY, 14009-9601
Project Congressional District NY-24
Number of Employees 85
NAICS code 331210
Borrower Race Unanswered
Borrower Ethnicity Unknown/NotStated
Business Type Subchapter S Corporation
Originating Lender ID 75967
Originating Lender Name Hiawatha National Bank
Originating Lender Address HAGER CITY, WI
Gender Unanswered
Veteran Unanswered
Forgiveness Amount 974437.17
Forgiveness Paid Date 2020-11-05

Date of last update: 23 Mar 2025

Sources: New York Secretary of State