Inspection Type |
Planned
|
Scope |
Partial
|
Safety/Health |
Safety
|
Close Conference |
2019-11-20
|
Emphasis |
L: FALL, P: FALL
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260451 A01 |
Issuance Date |
2020-05-07 |
Abatement Due Date |
2020-05-19 |
Current Penalty |
2892.0 |
Initial Penalty |
2892.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(a)(1): Scaffold(s) and scaffold(s) component(s) were not capable of supporting, without failure, its own weight and at least four times the maximum intended load applied or transmitted to it: Location: 5022 15th Avenue, Brooklyn, NY 11219 On or about: November 20, 2019 (a) An employee worked from a scaffold platform that was supported by scaffold components that were not designed for supporting loads. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260451 E01 |
Issuance Date |
2020-05-07 |
Current Penalty |
2892.0 |
Initial Penalty |
2892.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Location: 5022 15th Avenue, Brooklyn, NY 11219 On or about: November 20, 2019 (a) The employer did not ensure that safe means of access were provided for each employee; an employee climbed scaffold frames to access their working level. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260452 C02 |
Issuance Date |
2020-05-07 |
Current Penalty |
2892.0 |
Initial Penalty |
2892.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
1 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.452(c)(2): All brace connections were not secured: Location: 5022 15th Avenue, Brooklyn, NY 11219 On or about: November 20, 2019 (a) An employee worked from a 1-tier tubular welded frame scaffold that was not fully braced by cross braces. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260502 D06 I |
Issuance Date |
2020-05-07 |
Abatement Due Date |
2020-05-19 |
Current Penalty |
2892.0 |
Initial Penalty |
2892.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
2 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(d)(6)(i): A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. Location: 5022 15th Avenue, Brooklyn, NY 11219 On or about: November 20, 2019 (a) Employees wearing lanyards had snaphooks directly engaged to webbing. |
|
Citation ID |
01005 |
Citaton Type |
Serious |
Standard Cited |
19261052 C04 |
Issuance Date |
2020-05-07 |
Current Penalty |
2313.0 |
Initial Penalty |
2313.0 |
Final Order |
2020-06-01 |
Nr Instances |
1 |
Nr Exposed |
7 |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps: Location: 5022 15th Avenue, Brooklyn, NY 11219 On or about: November 20, 2019 (a) Midrails or equivalent structural members were not provided for the stairway leading to the 3rd floor. |
|
|