Filings

Filing Number Date Filed Type Effective Date
181203010638 2018-12-03 CERTIFICATE OF INCORPORATION 2018-12-03

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345508162 0215000 2021-09-01 5022 15TH AVE., BROOKLYN, NY, 11219
Inspection Type FollowUp
Scope Partial
Safety/Health Safety
Close Conference 2021-09-01
Emphasis L: FALL
Case Closed 2021-12-03

Related Activity

Type Inspection
Activity Nr 1446188
Safety Yes
344461884 0215000 2019-11-20 5022 15TH AVENUE, BROOKLYN, NY, 11219
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2019-11-20
Emphasis L: FALL, P: FALL

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 A01
Issuance Date 2020-05-07
Abatement Due Date 2020-05-19
Current Penalty 2892.0
Initial Penalty 2892.0
Final Order 2020-06-01
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(a)(1): Scaffold(s) and scaffold(s) component(s) were not capable of supporting, without failure, its own weight and at least four times the maximum intended load applied or transmitted to it: Location: 5022 15th Avenue, Brooklyn, NY 11219 On or about: November 20, 2019 (a) An employee worked from a scaffold platform that was supported by scaffold components that were not designed for supporting loads.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2020-05-07
Current Penalty 2892.0
Initial Penalty 2892.0
Final Order 2020-06-01
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Location: 5022 15th Avenue, Brooklyn, NY 11219 On or about: November 20, 2019 (a) The employer did not ensure that safe means of access were provided for each employee; an employee climbed scaffold frames to access their working level.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260452 C02
Issuance Date 2020-05-07
Current Penalty 2892.0
Initial Penalty 2892.0
Final Order 2020-06-01
Nr Instances 1
Nr Exposed 1
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.452(c)(2): All brace connections were not secured: Location: 5022 15th Avenue, Brooklyn, NY 11219 On or about: November 20, 2019 (a) An employee worked from a 1-tier tubular welded frame scaffold that was not fully braced by cross braces.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260502 D06 I
Issuance Date 2020-05-07
Abatement Due Date 2020-05-19
Current Penalty 2892.0
Initial Penalty 2892.0
Final Order 2020-06-01
Nr Instances 1
Nr Exposed 2
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.502(d)(6)(i): A snaphook not of the locking type was engaged (i) directly to webbing, rope or wire rope; (ii) to each other (iii) to a Dee-ring to which another snaphook or other connector is attached;(iv) to a horizontal lifeline; or (v) to any object which is incompatibly shaped or dimensioned in relation to the snaphook such that unintentional disengagement could occur by the connected object being able to depress the snaphook keeper and release itself. Location: 5022 15th Avenue, Brooklyn, NY 11219 On or about: November 20, 2019 (a) Employees wearing lanyards had snaphooks directly engaged to webbing.
Citation ID 01005
Citaton Type Serious
Standard Cited 19261052 C04
Issuance Date 2020-05-07
Current Penalty 2313.0
Initial Penalty 2313.0
Final Order 2020-06-01
Nr Instances 1
Nr Exposed 7
Gravity 5
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.1052(c)(4): Midrails, screens, mesh, intermediate vertical members, or equivalent intermediate structural members were not provided between the top rail of the stairrail system and the stairway steps: Location: 5022 15th Avenue, Brooklyn, NY 11219 On or about: November 20, 2019 (a) Midrails or equivalent structural members were not provided for the stairway leading to the 3rd floor.