Inspection Type |
Referral
|
Scope |
Complete
|
Safety/Health |
Safety
|
Close Conference |
2021-12-02
|
Emphasis |
L: FALL
|
Case Closed |
2023-06-29
|
Related Activity
Type |
Referral |
Activity Nr |
1834280 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1564026 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1566606 |
Safety |
Yes |
|
Type |
Inspection |
Activity Nr |
1566630 |
Safety |
Yes |
|
Violation Items
Citation ID |
01001 |
Citaton Type |
Serious |
Standard Cited |
19260057 A |
Issuance Date |
2022-02-02 |
Current Penalty |
2450.0 |
Initial Penalty |
3108.0 |
Final Order |
2022-03-01 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.57(a): The employer failed to ensure that concentrations of dusts, fumes, mists, vapors, or gases did not exceed the limits specified in 1926.55(a): On or about: December 2, 2021 Location: Dr. George W. Girling Dr. Haverstraw NY 10927 a) Honda EB 5000 X Generator and Rolair compressor were operating in close space area exposing employees to hazardous gases. |
|
Citation ID |
01002 |
Citaton Type |
Serious |
Standard Cited |
19260403 B02 |
Issuance Date |
2022-02-02 |
Current Penalty |
2450.0 |
Initial Penalty |
3108.0 |
Final Order |
2022-03-01 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.403(b)(2): Listed, labeled, or certified equipment was not installed and used in accordance with instructions included in the listing, labeling, or certification: On or about: December 2, 2021 Location: Dr. George W. Girling Dr. Haverstraw NY 10927 a) Employees were operating power tools that were connected to relocatable power tap (C664502) which was not UL approved for outdoor use exposing employees to electrical shock hazard. |
|
Citation ID |
01003 |
Citaton Type |
Serious |
Standard Cited |
19260501 B04 II |
Issuance Date |
2022-02-02 |
Current Penalty |
0.0 |
Initial Penalty |
3108.0 |
Final Order |
2022-03-01 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.501(b)(4)(ii):Covers were not provided for holes in which an employee on a walking/working surface could trip or step: On or about: December 2, 2021 Location: Dr. George W. Girling Dr. Haverstraw NY 10927 a) Employees were working in Building #4 near multiple 12x12 inch holes that were not covered exposing employees to fall hazards. |
|
Citation ID |
01004 |
Citaton Type |
Serious |
Standard Cited |
19260502 B01 |
Issuance Date |
2022-02-02 |
Current Penalty |
2100.0 |
Initial Penalty |
2486.0 |
Final Order |
2022-03-01 |
Nr Instances |
1 |
Nr Exposed |
4 |
Related Event Code (REC) |
Referral |
Gravity |
5 |
FTA Current Penalty |
0.0 |
Citation text line |
29 CFR 1926.502(b)(1): The top edge height of the top rails, or equivalent guardrail system members, was not 42 inches (1.1 m) plus or minus 3 inches (8 cm) above the walking/working level:Note: When employees are using stilts, the top edge height of the top rail, or equivalent member, shall be increased an amount equal to the height of the stilts. On or about: December 2, 2021 Location: Dr. George W. Girling Dr. Haverstraw NY 10927 a) Employees were working near guardrail that was approximately 34 inches high, and did not have mid rail exposing employees to fall hazard. |
|
|