Name: | RJM BEST ROOFING INC. |
Jurisdiction: | New York |
Legal type: | DOMESTIC BUSINESS CORPORATION |
Status: | Active |
Date of registration: | 27 Dec 2018 (6 years ago) |
Entity Number: | 5464706 |
ZIP code: | 10573 |
County: | Westchester |
Place of Formation: | New York |
Address: | 102 TOURAINE AVENUE #2, PORT CHESTER, NY, United States, 10573 |
Principal Address: | 102 Touraine ave #2, Port chester, NY, United States, 10573 |
Shares Details
Shares issued 20000
Share Par Value 1
Type PAR VALUE
Type | Company Name | Company Number | State |
---|---|---|---|
Headquarter of | RJM BEST ROOFING INC., CONNECTICUT | 2779368 | CONNECTICUT |
Name | Role | Address |
---|---|---|
THE CORPORATION | DOS Process Agent | 102 TOURAINE AVENUE #2, PORT CHESTER, NY, United States, 10573 |
Name | Role | Address |
---|---|---|
MARCELO YUPANGUI | Chief Executive Officer | 102 TOURAINE AVE #2, PORT CHESTER, NY, United States, 10573 |
Start date | End date | Type | Value |
---|---|---|---|
2021-11-13 | 2023-05-02 | Shares | Share type: PAR VALUE, Number of shares: 20000, Par value: 1 |
2018-12-27 | 2021-11-13 | Shares | Share type: PAR VALUE, Number of shares: 20000, Par value: 1 |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
220511001617 | 2022-05-11 | BIENNIAL STATEMENT | 2020-12-01 |
181227010181 | 2018-12-27 | CERTIFICATE OF INCORPORATION | 2019-01-01 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
347047136 | 0216000 | 2023-10-13 | 150 GAYLOR AVENUE, SCARSDALE, NY, 10583 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2024-02-15 |
Current Penalty | 3250.0 |
Initial Penalty | 5323.0 |
Final Order | 2024-05-22 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): A) 150 Gaylor Avenue, Scarsdale - NY: Employees were exposed to fall hazards of approximately 22 1/2-feet while conducting roofing replacement work, without the use of harnesses, or other fall protection devices, on or about, October 13th, 2023. |
Inspection Type | Planned |
Scope | Complete |
Safety/Health | Safety |
Close Conference | 2023-06-07 |
Emphasis | P: FALL, L: FALL |
Case Closed | 2024-08-19 |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19260102 A01 |
Issuance Date | 2023-08-08 |
Current Penalty | 3280.0 |
Initial Penalty | 5358.0 |
Contest Date | 2023-09-01 |
Final Order | 2024-01-05 |
Nr Instances | 1 |
Nr Exposed | 2 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.102(a)(1): Eye and face protective equipment were not used when machines or operations presented potential eye or face injury from physical, chemical, or radiation agents. A) 122 Hollywood Avenue, Yonkers - NY: Employees were exposed to eye/face injuries while using pneumatic nail guns during roofing work. The employees were not protected by eye/face protection, on or about, June 7th 2023. |
Citation ID | 01002 |
Citaton Type | Serious |
Standard Cited | 19260501 B13 |
Issuance Date | 2023-08-08 |
Current Penalty | 3826.0 |
Initial Penalty | 6250.0 |
Contest Date | 2023-09-01 |
Final Order | 2024-01-05 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Imminent Danger |
Gravity | 10 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.501(b)(13): Each employee(s) engaged in residential construction activities 6 feet (1.8 m) or more above lower levels were not protected by guardrail systems, safety net system, or personal fall arrest system, nor were employee(s) provided with an alternative fall protection measure under another provision of paragraph 1926.501 (b): A) 122 Hollywood Avenue, Yonkers - NY: Employees were exposed to fall hazards of approximately 20 feet (back roof) and 27 feet (main roof) while conducting roofing replacement work on a roof, without the use of harnesses or other fall protection devices, on or about, June 7th, 2023. |
Citation ID | 01003 |
Citaton Type | Serious |
Standard Cited | 19261053 B01 |
Issuance Date | 2023-08-08 |
Current Penalty | 2734.0 |
Initial Penalty | 4465.0 |
Contest Date | 2023-09-01 |
Final Order | 2024-01-05 |
Nr Instances | 1 |
Nr Exposed | 3 |
Related Event Code (REC) | Imminent Danger |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1926.1053(b)(1): Portable ladders were used for access to an upper landing surface, the ladder side rails did not extend at least 3 feet above the upper landing surface to which the ladder is used to gain access: A) 122 Hollywood Avenue, Yonkers - NY: Employees were exposed to fall hazards of approximately 27 feet while using an extension ladder to access a roof. The extension ladder that was used, did not extend at least 3 feet above the landing, on or about, June 7th, 2023. |
Date of last update: 23 Mar 2025
Sources: New York Secretary of State