Search icon

LINK GENERAL CONTRACTING CORP

Company Details

Name: LINK GENERAL CONTRACTING CORP
Jurisdiction: New York
Legal type: DOMESTIC BUSINESS CORPORATION
Status: Active
Date of registration: 15 Jan 2019 (6 years ago)
Entity Number: 5475509
ZIP code: 10307
County: Richmond
Place of Formation: New York
Address: 6 ADLERS LANE, STATEN ISLAND, NY, United States, 10307

Shares Details

Shares issued 200

Share Par Value 0

Type NO PAR VALUE

DOS Process Agent

Name Role Address
THE CORPORATION DOS Process Agent 6 ADLERS LANE, STATEN ISLAND, NY, United States, 10307

History

Start date End date Type Value
2022-06-28 2023-08-07 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0
2019-01-15 2022-06-28 Shares Share type: NO PAR VALUE, Number of shares: 200, Par value: 0

Filings

Filing Number Date Filed Type Effective Date
190115010137 2019-01-15 CERTIFICATE OF INCORPORATION 2019-01-15

OSHA's Inspections within Industry

Inspection Nr Report ID Date Opened Site Address
345577514 0215000 2021-10-13 1199 EAST 53RD STREET, BROOKLYN, NY, 11234
Inspection Type Planned
Scope Partial
Safety/Health Safety
Close Conference 2021-10-13
Emphasis L: FALL, L: LOCALTARG, P: LOCALTARG

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2022-02-10
Current Penalty 4351.0
Initial Penalty 4351.0
Contest Date 2022-02-17
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms were more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from other scaffold, structure, personnel hoist, or similar surface was not used. Crossbraces were used as a means of access. Location: a) Scaffold a) On or about 10/13/2021, employees climbed the crossbraces and scaffold frames to access the working platforms.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 G01 VII
Issuance Date 2022-02-10
Current Penalty 4351.0
Initial Penalty 4351.0
Contest Date 2022-02-17
Nr Instances 1
Nr Exposed 3
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(g)(1)(vii): Each employee on a scaffold, not otherwise specified in paragraphs (g)(1)(i) through (g)(1)(vi) of this section, more than 10 feet (3.1 m) above lower level was not protected from falls by the use of personal fall arrest systems or guardrail systems meeting the requirements of paragraph (g)(4) of this section. Location: a) Scaffold a) On or about 10/13/2021, employees worked on a scaffold that was not equipped with guardrails. Employees exposed to a fall of 12 feet.
345279335 0215000 2021-04-23 1200 EAST 53RD STREET, BROOKLYN, NY, 11234
Inspection Type Fat/Cat
Scope Partial
Safety/Health Safety
Close Conference 2021-04-23
Emphasis L: FALL

Related Activity

Type Referral
Activity Nr 1762651
Safety Yes
Health Yes
Type Accident
Activity Nr 1764040
Type Inspection
Activity Nr 1547487
Safety Yes

Violation Items

Citation ID 01001
Citaton Type Serious
Standard Cited 19260451 B02
Issuance Date 2021-10-21
Abatement Due Date 2021-10-28
Current Penalty 4096.0
Initial Penalty 4096.0
Contest Date 2021-11-10
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(b)(2): Scaffold platforms and walkways were not at least 18 inches wide. Site: 1200 East 53rd Street in Brooklyn, NY. On or about 4/23/2021, a) Employees worked on top the sidewalk shed and crossed onto the 2-point suspended scaffold using a 9.25 inch wide plank. The platform used to cross was not at least 18 inches wide.
Citation ID 01002
Citaton Type Serious
Standard Cited 19260451 E01
Issuance Date 2021-10-21
Abatement Due Date 2021-10-28
Current Penalty 4096.0
Initial Penalty 4096.0
Contest Date 2021-11-10
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(1): When scaffold platforms are more than 2 feet (0.6 m) above or below a point of access, portable ladders, hook-on ladders, attachable ladders, stair towers (scaffold stairways/towers), stairway-type ladders (such as ladder stands), ramps, walkways, integral prefabricated scaffold access, or direct access from another scaffold, structure, personnel hoist, or similar surface shall be used. Crossbraces shall not be used as a means of access. Site: 1200 East 53rd Street in Brooklyn, NY. On or about 4/23/2021, a) Employees on site accessed the 2-point suspended scaffold platform using an unsecured plank placed in the guardrail of the suspended scaffold. The employees climbed over the railing of the suspended scaffold from a single plank approximately 10 feet above the ground.
Citation ID 01003
Citaton Type Serious
Standard Cited 19260451 E05 I
Issuance Date 2021-10-21
Abatement Due Date 2021-10-28
Current Penalty 4096.0
Initial Penalty 4096.0
Contest Date 2021-11-10
Nr Instances 1
Nr Exposed 2
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(e)(5)(i): Ramps and walkways 6 feet (1.8 m) or more above lower levels shall have guardrail systems which comply with subpart M of this part -- Fall Protection. Site: 1200 East 53rd Street Brooklyn, NY On or about 4/23/2021. a) Employees working at the site accessed the raised 2-point suspended scaffold using a single plank. The walkway to the scaffold did not have guardrail systems as required to protect the employees from falling.
Citation ID 01004
Citaton Type Serious
Standard Cited 19260451 F03
Issuance Date 2021-10-21
Abatement Due Date 2021-10-28
Current Penalty 4096.0
Initial Penalty 4096.0
Contest Date 2021-11-10
Nr Instances 1
Nr Exposed 3
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.451(f)(3):Scaffolds and scaffold components were not inspected for visible defects by a competent person before each work shift, and after any occurrence which could affect a scaffold's structural integrity: Site: 1200 East 53rd Street Brooklyn, NY On or about 4/23/2021. a) Employees bridged a sidewalk shed and a raised 2-point suspended scaffold with a single plank for access. The plank was not secured and and did not have the structural integrity to support employees' crossing. There was no competent person on site to inspect for the structural integrity of the plank.
Citation ID 01005
Citaton Type Serious
Standard Cited 19260454 A
Issuance Date 2021-10-21
Abatement Due Date 2021-11-02
Current Penalty 4096.0
Initial Penalty 4096.0
Contest Date 2021-11-10
Nr Instances 1
Nr Exposed 4
Related Event Code (REC) Accident
Gravity 10
FTA Current Penalty 0.0
Citation text line 29 CFR 1926.454(a): The employer did not have each employee who performed work on a scaffold be trained by a person qualified in the subject matter to recognize the hazards associated with the type of scaffold being used, and to understand the procedures to control or minimize those hazards. Site: 1200 East 53rd Street in Brooklyn, NY. On or about 4/23/2021, a) Employees on site accessed and worked on the 2-point suspended scaffold without recognizing the hazards associated with the procedures performed. The employees were not trained in hazards related to scaffold use.

Date of last update: 06 Mar 2025

Sources: New York Secretary of State