Name: | U.S. SUGAR CO., LLC |
Jurisdiction: | New York |
Legal type: | FOREIGN LIMITED LIABILITY COMPANY |
Status: | Active |
Date of registration: | 16 Jan 2019 (6 years ago) |
Entity Number: | 5476716 |
ZIP code: | 10528 |
County: | Erie |
Place of Formation: | Delaware |
Address: | 600 MAMARONECK AVENUE #400, HARRISON, NY, United States, 10528 |
Name | Role | Address |
---|---|---|
CORPORATE CREATIONS NETWORK INC. | Agent | 600 MAMARONECK AVENUE #400, HARRISON, NY, 10528 |
Name | Role | Address |
---|---|---|
C/O CORPORATE CREATIONS NETWORK INC. | DOS Process Agent | 600 MAMARONECK AVENUE #400, HARRISON, NY, United States, 10528 |
Start date | End date | Type | Value |
---|---|---|---|
2023-02-12 | 2025-01-21 | Address | 600 MAMARONECK AVENUE #400, HARRISON, NY, 10528, USA (Type of address: Registered Agent) |
2023-02-12 | 2025-01-21 | Address | 600 MAMARONECK AVENUE #400, HARRISON, NY, 10528, USA (Type of address: Service of Process) |
2019-01-16 | 2023-02-12 | Address | 15 NORTH MILL STREET, NYACK, NY, 10960, USA (Type of address: Service of Process) |
Filing Number | Date Filed | Type | Effective Date |
---|---|---|---|
250121003181 | 2025-01-21 | BIENNIAL STATEMENT | 2025-01-21 |
230201002081 | 2023-02-01 | BIENNIAL STATEMENT | 2023-01-01 |
230212000295 | 2022-06-01 | CERTIFICATE OF CHANGE BY ENTITY | 2022-06-01 |
190116000631 | 2019-01-16 | APPLICATION OF AUTHORITY | 2019-01-16 |
Inspection Nr | Report ID | Date Opened | Site Address | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
346785652 | 0213600 | 2023-06-22 | 692 BAILEY AVENUE, BUFFALO, NY, 14206 | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
Type | Complaint |
Activity Nr | 2043907 |
Safety | Yes |
Violation Items
Citation ID | 01001 |
Citaton Type | Serious |
Standard Cited | 19100212 A01 |
Issuance Date | 2023-07-25 |
Abatement Due Date | 2023-08-16 |
Current Penalty | 4554.0 |
Initial Penalty | 7590.0 |
Final Order | 2023-08-17 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.212(a)(1): One or more methods of machine guarding was not provided to protect the operator and other employees in the machine area from hazards such as those created by rotating parts: a) On or about 06/22/2023 on the third floor at the Vase Line; where employees were exposed to unguarded/inadequately guarded rotating parts on the Sleever and the Capper. ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002A |
Citaton Type | Serious |
Standard Cited | 19100303 B02 |
Issuance Date | 2023-07-25 |
Abatement Due Date | 2023-08-16 |
Current Penalty | 4554.0 |
Initial Penalty | 7590.0 |
Final Order | 2023-08-17 |
Nr Instances | 2 |
Nr Exposed | 4 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.303(b)(2):Listed or labeled electrical equipment was not used or installed in accordance with instructions included in the listing or labeling: a) On or about 06/22/2023 on the third floor at Vase Line; where a metal duplex receptacle box with holes and knockouts was used at the end of a flexible cable as an extension cord. The box was on the floor, not mounted in place as required by the National Electrical Code. b) On or about 06/22/2023 on the third floor at the Vase Line; where electrical motor loads (two pedestal floor fans) were being powered by a Temporary Power Tap (power strip). ABATEMENT CERTIFICATION REQUIRED |
Citation ID | 01002B |
Citaton Type | Serious |
Standard Cited | 19100305 G01 IV A |
Issuance Date | 2023-07-25 |
Abatement Due Date | 2023-08-16 |
Current Penalty | 0.0 |
Initial Penalty | 0.0 |
Final Order | 2023-08-17 |
Nr Instances | 1 |
Nr Exposed | 4 |
Related Event Code (REC) | Complaint |
Gravity | 5 |
FTA Current Penalty | 0.0 |
Citation text line | 29 CFR 1910.305(g)(1)(iv)(A):Flexible cords and/or cables were used as a substitute for the fixed wiring of a structure: a) On or about 06/22/2023 on the third floor at the Vase Line; where an extension cord was used in place of fixed wiring to supply power to floor fans and equipment. ABATEMENT CERTIFICATION REQUIRED |
Date of last update: 23 Mar 2025
Sources: New York Secretary of State